Centrifugal Separation Sand Mill

The centrifugal separation sand mill generates centrifugal force through high-speed rotation to achieve separation between grinding media and materials. It is used for wet grinding in industries such as coatings and inks, enabling control over particle fineness, reducing agglomeration, and improving dispersion uniformity.
Selection
When selecting a centrifugal separation sand mill, considerations should include material viscosity, target fineness, and processing capacity. Match the grinding media material and size, evaluate equipment energy consumption and ease of operation, and ensure compatibility with the production process.

Terms

Standards

Instruments

Using 1400rpm speed regulation and 1.5 liters effective volume sand grinding basket, rapid dispersion and grinding are achieved through tensile shear and Impact between sand and material, and the operation is simple.

$ 574.00

Centrifugal separation device to achieve large Flow rate discharge, equipped with double mechanical sealing and double chill down mode, grinding Chamber capacity of 0.3L, Power 1.5kw, effective control of ground heat and ensure stable operation.

$ 6205.00

Set dispersion and sand grinding functions in one, complete two processes in a single container, speed range 130~ 3000rpm, grinding basket size Φ 80x60mm, high efficiency and easy to clean.

$ 1413.00

The variable frequency motor is used to achieve stepless speed regulation from 0 to 7500 rpm, equipped with dispersed impeller and sand grinding blades, and the dual-axis constant force lifting system has a stroke of 200mm, which can adapt to different experimental requirements and calculate the material reaction relationship.

$ 816.00

1400 rpm high-speed stirring is used to achieve strong tensile shear and Impact between the material and the sand, and the fineness of grinding can reach 25 microns or less, suitable for sample testing, with a capacity of 1.5 liters.

$ 751.00

1400 rpm high-speed stirring is used to achieve strong tensile shear and Impact between the material and the sand, the fineness of grinding can reach 25 microns or less, and the capacity is 1.5 liters, which is suitable for laboratory sample dispersion grinding.

$ 619.00

Using dual-axis constant force lifting system and variable frequency motor, 0-3000rpm stepless speed regulation, equipped with dispersed impeller and sand grinding blades, can directly calculate the relationship between material viscosity and reaction rate.

$ 493.00

The linear velocity of blade disk is 10.5 m/s, the volume of material barrel is 1.8 L, and the aggregates are destroyed by strong impact and shearing to achieve high-efficiency dispersion and mixing, which is suitable for liquid material experiments.

$ 1171.00

Using 1320rpm high-speed dispersion shaft, equipped with 30L grinding cylinder to achieve strong shear impact on the ground, sieve discharge design is easy to clean and change color, adapt to different material fineness adjustment.

$ 3785.00

Continuously variable frequency speed regulation 0-3000rpm, ground medium 0.8-2 mm, stable operation and low noise, can work continuously for a long time, suitable for medium and low viscosity fluids.

$ 3301.00

Cylinder volume 40L with 1020rpm dispersion shaft Rotation speed, can achieve continuous and efficient grinding dispersion, sieve discharge design is easy to change color cleaning operation

$ 4269.00

Cylinder volume 120L, Rotation speed of dispersion shaft 700rpm, using sieve discharge design, can adjust the grinding medium to adapt to different fineness requirements, to achieve continuous and efficient pRoduction.

$ 8126.00

Cylinder volume 80L with 830rpm dispersion shaft Rotation speed, to achieve efficient ground dispersion; sieve discharge design for easy cleaning and color change, to adapt to different material process requirements.

$ 6205.00

Compression stroke 2.50mm, load 237g, suitable for wet mold sand/core surface Hardness measurement, support USB and Bluetooth data output, with average calculation and undervoltage alarm function.

$ 328.00

Suitable for medium and high viscosity materials, using bottom open turbine structure with strong suction pump effect, grinding medium diameter 0.8-2 mm, variable frequency speed range 0-1440rpm, equipped with chill down heating jacket to control material temperature.

$ 4592.00

Articles

Friction Coefficient Tester Measures the Slip and Openability of Films
This article introduces how to use a coefficient of friction tester to measure the slipperiness and openability of films. Slipperiness refers to the sliding characteristics of the film surface, while openability indicates the ease of separation between film layers. Both are crucial for processing efficiency in industries such as packaging.
Internal Bond Strength Scott Tester for evaluating interlayer bonding force of paper.
This article introduces the method of evaluating the interlayer bonding strength of paper using a Scott tester. The interlayer bonding strength affects the printing and mechanical properties of paper. During testing, the instrument peels the paper vertically through an adhesive test head, records the energy required for separation, and calculates the internal bond strength.
Bauer-McNett Classifier Method and Fiber Fractionation Principle of Pulp Fiber Classifier
The Bauer-McNett classifier is a standard method that separates fibers by length and morphology through the sequential screening of pulp suspensions using sieves with different aperture sizes.
The ink tack meter measures the tack value of printing inks.
This article introduces how the ink tack meter measures the tack value of printing ink. The tack value reflects the ink's ability to resist separation during printing, which is important for controlling print quality.
Principles and Advantages of Ion Chromatography for Determining Anions in Water
Ion chromatography separates anions in water samples through an ion exchange column, then reduces background conductivity and enhances signals via a suppressor, and finally measures and quantifies them using a conductivity detector.
The role of the screening analyzer in pulp fiber morphology analysis
The screening analyzer separates pulp fibers through standard sieves to analyze their length distribution. Morphological parameters such as fiber length and coarseness directly affect paper properties like strength and bulk.
Comparison of Pigment Fineness Dispersion between Flat Grinding Mill and Sand Mill
Pull-off testing for interlayer adhesion of multilayer coating systems.
This article introduces the pull-off method for testing the interlayer adhesion of multilayer coating systems. The test involves vertically bonding a pull-off head to the coating surface and applying a pulling force until the coating separates, measuring the required force to evaluate adhesion strength.
Application of Initial Tack Tester in the Adhesive Products Industry
The initial tack tester is used to measure the adhesive force of adhesive products upon initial contact, which is important for the research, development, and quality control of products such as tapes and labels. It simulates the process of materials making contact and then separating, records relevant data, and helps evaluate performance.