Coating Paint Scraper Rod

The coating drawdown bar is a coating tool made of metal or plastic, featuring grooves of varying depths on its surface. After applying the coating onto the substrate, the bar is drawn across at a fixed angle, with the grooves controlling the wet film thickness. It is used in laboratories to prepare uniform coating films for testing properties such as hiding power and color difference.
Selection
When selecting, consider the substrate roughness; choose a deep-grooved applicator for rough surfaces. Determine the wet film thickness according to the testing standards, corresponding to the groove depth of the applicator. For high-viscosity coatings, opt for wide-grooved types. Stainless steel material resists solvents, while plastic material prevents scratching the substrate. Groove shapes include square and round, with square ones being easier to clean.

Terms

Standards

Instruments

Wire-wound design, film thickness 120 microns, total length 37.5cm, effective application width 25.5cm, stainless steel material to ensure durability and uniform Spreader.

$ 173.00

It can prepare a wet film thickness of 13.7 microns, with a wire-wound design providing stable coating performance. The 9.52 mm diaMeter ensures easy operation, making it suitable for various paint application scenarios.

$ 167.00

Using removable scraper and vacuum adsorption system, Spreader accuracy +/- 0.003mm, Spreader rate 5~ 180mm/s, heating temperature up to 180 ℃, improve film Stability and uniformity.

$ 7496.00

A wet film with a film thickness of 50~ 675 μ m was prepared by using a coating scraper, and the sag property was observed when placed vertically. The maximum thickness without sag was expressed, which was suitable for Paints testing.

$ 411.00

The extrusion production process ensures uniform coating, with a wet film thickness of 60μm meeting the demands of precise experiments. The 304 stainless steel material is durable and easy to clean, making it suitable for diverse coating performance tests.

$ 178.00

With bar and Drawdown blade two Spreader mode, using clamshell Drawdown blade head and new bar Installation method, easy to clean. Spreader speed and length can be freely adjusted, film thickness control accuracy is high, suitable for Glass, cardboard and other substrates.

$ 2978.00

The kit can realize automatic grinding fineness Gauge operation, improve test Repeatability, suitable for standard scraper fineness Meter supporting use, simplify the experimental process.

$ 1623.00

Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.

$ 120.00

Wet film thickness 45μm, main Rod diaMeter 10mm, effective application width 600mm, using SUS304 material, Coating Weight, length and surface preparation can be customized, suitable for a variety of Spreader conditions.

$ 267.00

Wet film thickness 22.9 microns, diaMeter 9.52 mm, the forming Rod uses an extrusion process to process continuous grooves, with no wire breakage and easy cleaning; the wire-wound Rod is based on the traditional principle, and there are differences in coating amount.

$ 167.00

Imported wire Rod to achieve 1 μ m High Accuracy Spreader, scraper Spreader Film thickness range of 0~ 5000 μ m, support 5~ 200mm/s stepless speed control and vacuum adsorption fixation, effectively improve film conformity and operation convenience.

$ 3494.00

It can measure the ability of the paint film to deform with the substrate without damage. It is equipped with a shaft Rod with a diaMeter of 50mm and 100mm.

$ 309.00

The multi-groove coating scraper can scrape 10 wet-films of different thicknesses at one time, the thickness difference of adjacent films is 25um, and the wide film thickness range of 50-675um is supported. It is convenient to visually observe the sag situation by placing the test plate vertically.

$ 315.00

Adopt high-quality alloy steel scraper, Hardness and wear resistance and corrosion resistance; Magnetic suction design for quick replacement and cleaning; Film Film thickness 0~ 4500 μ m free adjustment, resolution up to 10 μ m, error only +/- 2 μ m.

$ 291.00

The paint film adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel was 80mm. The integrity of the paint film was evaluated according to seven grades, and the operation was simple and reliable.

$ 267.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.