Vertical Blowing Box

Vertical air circulation ovens circulate hot air through a fan to ensure uniform temperature inside the chamber. They are used for drying, curing, and aging tests of materials, such as processing paint samples and drying plastic parts in laboratory settings. The vertical structure of the oven saves space, and its temperature control range covers from room temperature to 300℃.
Selection
Determine the inner chamber volume based on sample dimensions, with standard specifications ranging from 30L to 1000L. Select the temperature range according to process requirements, paying attention to the fluctuation range of ±1℃ to ±5℃. The stainless steel inner chamber is corrosion-resistant, and the observation window facilitates monitoring. Consider the power supply capacity and exhaust port configuration, with adjustable air volume to accommodate different materials.

Terms

Standards

Instruments

Vertical double air duct air sleeve with turbine centrifugal forced air supply, Temperature Uniformity of +/- 2.5%; Speed control fan supports lightweight and small Sample Handling to ensure long-term stable operation of the equipment.

$ 942.00

Vertical double air duct air sleeve structure with turbine centrifugal forced air supply, Temperature Uniformity of +/- 2.5%; Speed control fan design supports light and small Sample Handling, fan operating temperature below 50 ℃ to ensure long-term stable operation.

$ 1006.00

Vertical double air duct centrifugal forced air supply, Temperature Uniformity +/- 2.5%, speed regulating fan to adapt to light and small samples, over-lift preventer to ensure safe operation, Temperature range RT + 10~ 300 ℃.

$ 848.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy +/- 1.0 ℃, turbine centrifugal fan blades with the bottom drum design, switch fan adjustable to prevent blowing powder items.

$ 912.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.

$ 1474.00

Vertical double air duct vertical hot air circulation to ensure Temperature uniformity, temperature control accuracy +/- 1.0 ℃, switch fan can avoid blowing powder items, equipped with Touchscreen support program temperature control and data recording function.

$ 1687.00

Temperature control accuracy of +/- 1 ℃, equipped with speed regulating fan to adapt to lightweight samples; double air duct air sleeve design to ensure temperature uniformity, forced cooling structure to prolong fan life, support fixed value timing operation and multiple safety protection functions.

$ 780.00

The fixture can fix the upper and lower ends of the butterfly specimen into a vertical shape, test the vertical compression strength, suitable for a variety of Corrugated Board types, Dimension 150 * 105 * 65mm, weight about 2Kg, easy to operate.

$ 596.00

Using 3mm thick A3 steel plate and SUS201 stainless steel inner box, the size of each test box is 500 * 500 * 500mm, with pressure relief device and temperature and pressure control, effectively preventing battery explosion and ensuring safe operation.

$ 1535.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Double needle automatic switching angle to improve condensing efficiency, support 1-8 bit Sample Handling, temperature control accuracy of +/- 0.5 ℃, with independent nitrogen channel and overheating protection to ensure safe and stable operation.

$ 7496.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Support forward and reverse rewinding and unwinding functions, with tension control and deviation correction functions, vertical mesh running speed 1mm/s to 1m/min, effective coating area 1500 * 600mm, to ensure that the mesh vertical stability without shaking.

$ 14274.00