Non-Metal Substrate Thickness Gauge

Non-metallic substrate thickness gauges utilize the principles of electromagnetic induction or eddy current to measure changes in the distance between the probe and the substrate, converting these changes into thickness values. They are used to detect the coating thickness on non-metallic materials such as plastics and wood, ensuring uniformity in coating applications.
Selection
When selecting, consider the substrate type and coating characteristics to match the measurement principle; choose an appropriate range and probe size based on accuracy requirements and operating environment; verify the instrument's calibration stability to ensure measurement repeatability.

Terms

Standards

Instruments

Measurement range 0~ 1500 microns, error +/- 1%, support magnetic Induction principle, IP65 Protection Rating and 250 reading storage, suitable for ferrous metal substrate nonmagnetic coating environment.

$ 890.00

Using high-speed ADC data collection, resolution up to 1μm, can simultaneously measure the thickness of multi-layer coatings or coatings plus substrates, with gain automatic switching and estimated thickness setting function, Measurement range 13~ 1000μm (epoxy resin coating).

$ 1132.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Using ultrasonic technology implementation nondestructive measurement, Measurement range 50~ 3800μm, accuracy +/- 3%, with weatherproof design, support USB data transmission and a variety of Unit switching, suitable for a variety of substrate conditions.

$ 3117.00

High-speed ADC data collection to achieve 1 μm resolution, with multi-layer coatings simultaneous measurement function, measurement range covering 13~ 1000 μm (epoxy resin) and 300~ 14800 μm (45 #steel), support waveform display and automatic gain switching.

$ 1132.00

Built-in FN3 Probe automatically recognizes the substrate, Measurement range 0~ 1500 μm, resolution 0.1 μm, Protection Rating IP65, can measure more than 180 readings per minute, support 250,000 Data storage.

$ 1858.00

Measurement range 0-1000 microns with dual-function Probe design, wear-resistant Ruby Probe and V-groove structure, support for automatic substrate identification and zero point Adjustment.

$ 841.00

Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.

$ 320.00

Measurement range 0~ 1250 microns, minimum substrate 0.3mm, with continuous testing, Data storage and a variety of calibrating modes, easy operation and high accuracy.

$ 364.00

Adopt magnetic eddy current integrated Probe, automatically identify the substrate, Measurement range 0-3000μm, accuracy +/- 2%, wear-resistant Probe life over 500,000 times, support single point and multi-point calibrating, adapt to various environments.

$ 227.00

Using magnetic Induction and eddy Current dual principle, automatic identification of substrate type, Measurement range 0~ 6000 μm, accuracy +/- 3%, equipped with 30mm wear resistant Probe, can obtain more than 60 readings per minute, Protection Rating IP65.

$ 1597.00

Measurement range 0~ 6000μm, error +/- 3%, automatic identification of substrate type, equipped with wear-resistant Probe and STDP1 calibration standard board, support Bluetooth data transmission and real-time graphic display, Protection Rating IP65.

$ 2115.00

Using magnetic Induction and eddy Current dual principle, automatically identify magnetic or nonmagnetic substrate, Measurement range 0~ 1500 μm, resolution up to 0.1 μm, support more than 180 readings per minute and high Protection Ratings.

$ 2055.00

Adopting the principle of magnetic thickness measurement, the range can reach 13000 μm, the error range is +/- 3%, with two methods of continuous measurement and single measurement, supporting large-capacity storage and upper and lower limit alarm functions, and the wear-resistant alloy probe is sturdy and durable.

$ 743.00

Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.

$ 359.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.