Circulating water pump for cooling tower

The circulating water pump for the cooling tower is driven by a motor to rotate the impeller, generating centrifugal force to transport cooling water from the collection pool to the cooling tower water distribution system. This enables the continuous circulation of the cooling medium between the heat exchange equipment and the cooling tower. It is applied in industrial cooling systems to ensure the fluid dynamics of the heat exchange process.
Selection
Determine the operating point of the pump based on the total flow rate and head of the cooling system, and match the motor power accordingly. Select corrosion-resistant materials considering water quality characteristics. Verify the installation space to choose between horizontal or vertical structures. Check the interface dimensions for compatibility with the piping. Confirm that the protection rating is suitable for the on-site environment.

Terms

Instruments

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 5271.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety protections such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 4437.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 1156.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 1774.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 3586.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.

$ 5828.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature runaway alarm to ensure the stability and safety of the experimental process.

$ 2241.00

Temperature control accuracy up to +/- 2 ℃, cooling capacity up to 10000W, equipped with 30L/min Flow rate adjustable circulating pump and anti-corrosion material system, support fast lifting and temperature multi-instrument function

$ 4492.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, and is equipped with multiple Safety protection devices including power-off protection and temperature alarm functions to ensure the stability and reliability of the experimental process.

$ 1990.00

Using circulating water as the working fluid, the maximum Vacuum Level is -0.098Mpa, the pumping rate is 80L/min, the special fluid muffler reduces the noise, the double tap design can be used alone or in combination, and the ABS engineering plastic shell is resistant to corrosion.

$ 267.00

Temperature range -20~ 100 ℃, cooling capacity 700W, built-in pressure suction pump Flow rate up to 22L/min, support high temperature direct drop and short-term idling of the pump head, long service life.

$ 1890.00

Proportional refrigeration technology and high temperature direct drop technology, Temperature range -80~ 40 ℃, cooling capacity 400W, built-in pressure suction pump, Flow rate 12L/min, support short time idling and impurity resistance.

$ 4677.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices such as power-off protection and temperature alarm to ensure stable operation of the equipment.

$ 4195.00

Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.

$ 3151.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with large-screen LCD display and PID automatic temperature control to ensure stable and safe operation.

$ 942.00

Articles