Drying Thermostatic Oven

The drying incubator uses electric heating elements and a temperature control system to maintain a constant temperature inside the chamber, enabling samples to rapidly remove moisture or remain dry at the set temperature. It is used in laboratories for material drying, curing, aging tests, and general constant-temperature storage.
Selection
When selecting, consider that the temperature range must cover experimental needs, uniformity affects heating consistency of samples, and capacity is determined by sample size and quantity. Pay attention to heating rate and temperature stability, ensure material corrosion resistance suits the usage environment, and opt for a user-friendly interface that is easy to maintain.

Terms

Standards

Instruments

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and observation window, uniform and stable heating, suitable for long-term thermostatic drying.

$ 441.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and observation window, uniform and stable heating, suitable for long-term thermostatic drying needs.

$ 557.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with intelligent digital display and observation window, uniform and stable heating, suitable for a variety of material drying needs.

$ 356.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.

$ 580.00

Temperature control accuracy of +/- 1 ℃, Temperature Uniformity +/- 2 ℃, with overheating alarm and timing function, low noise hot air circulation system to ensure uniform drying, optional RS-485 interface connection recorder.

$ 449.00

Adopt hot air circulation system to ensure Temperature Uniformity +/- 2 ℃, support 1-9999 minutes timing control, with RS-485 communication interface optional, suitable for drying and sterilizing operations.

$ 333.00

Temperature control accuracy of +/- 1 ℃ and uniformity of +/- 2 ℃, using low noise hot air circulation system directly drying objects, with over-temperature alarm and 1-9999 minutes timing function, support RS-485 communication interface to record data.

$ 415.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Adopt PID control technology to ensure Temperature Fluctuation +/- 1%, mirror stainless steel liner to prevent acid and alkali corrosion, Inner Chamber dimensions 420 * 450 * 350mm to facilitate sample access, combined with good air duct design to ensure Temperature uniformity.

$ 570.00

Intelligent PID control technology, Temperature Fluctuation +/- 1%, mirror stainless steel liner anti-acid and alkali corrosion, air duct design to ensure uniform temperature, with RS485 Communication interface and independent temperature limiter optional.

$ 729.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
The coating machine applies the adhesive layer of the plaster patch onto the backing layer.
The coating machine applies adhesive evenly onto the backing material through steps such as feeding, coating, drying, and winding, forming a stable adhesive layer.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Zero-span tensile strength tester measures the tensile strength of wet pulp.
This article introduces the method of measuring the tensile strength of wet pulp using a zero-span tensile strength tester. Traditional testing is often conducted after the pulp is dried, but testing in the wet state can more directly reflect the bonding potential between fibers.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
Drying Time Determination: Simultaneous Verification of Surface Drying Test Method, Through-Drying Test Method, and Instrumental Test Method
This article discusses three methods for determining the drying time of materials such as coatings. Traditional methods are divided into surface drying and through drying measurements, which are simple to operate but rely on subjective judgment. Instrumental methods provide objective data by monitoring physical changes such as mass and resistance, offering higher precision but at a higher cost.
Preparation of Paint Film Test Panels
The standardized preparation of paint film test panels is fundamental for accurately assessing the performance of paint films. The entire process includes key steps such as substrate selection and pretreatment, paint preparation, coating, drying and curing, thickness measurement, and curing.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.