Temperature-modulated magnetic stirrer

The temperature-controlled magnetic stirrer drives the magnetic stir bar inside the container to rotate by spinning the magnet at the bottom, achieving liquid mixing while the heating plate controls the temperature. It is used for reactions in the laboratory that require uniform heating and stirring, such as dissolution, synthesis, and other processes.
Selection
When selecting, consider matching the stirring capacity with the container size, ensuring the temperature range covers experimental needs, adjustable speed for effective mixing, corrosion-resistant and easy-to-clean materials, and safety features including overheating protection and a stable base.

Terms

Standards

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Using brushless DC motor to achieve stepless speed regulation of 0~ 1500rpm, equipped with strong magnetic steel to ensure strong stirring force and stable Rotation speed, Temperature range RT +~ 150 ℃, Heating power 360W adjustable, support mechanical timing 20~ 120min.

$ 212.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

Brushless DC motor and strong magnetic steel, Max. stirring Capacity 10L, temperature control accuracy +/- 1 ℃, with automatic temperature control function and Heating power stepless adjustment.

$ 249.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Driven by three-phase brushless DC motor, Rotation speed 50-1500rpm can be adjusted smoothly, temperature control accuracy +/- 0.5 ℃, with soft start anti-hopper and temperature protection functions, suitable for long-term unattended operation.

$ 424.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, digital display Rotation speed is clear and intuitive, suitable for large-capacity stirring needs.

$ 545.00

Magnetic surface temperature measurement Probe through strong magnetic adsorption on the workpiece, small volume and light mass, Sensor and magnet insulation to ensure measurement accuracy, the highest temperature 480 ℃, especially suitable for circular workpiece surface.

$ 666.00

Rotation speed is smooth and not affected by Power supply frequency by brushless DC motor, Max. stirring Capacity is up to 20L, strong magnetic force and strong structure, high power voltage regulation output and Rotation speed and voltage display function.

$ 322.00

Max. stirring Capacity 1000mL, Speed range 0-1600rpm, using magnetic field drive technology implementation of non-contact stirring, suitable for a variety of low viscosity liquid mixing needs.

$ 107.00

Four-station independent operation does not interfere with each other, the brushless DC motor provides 12.5mN · M torque, temperature control accuracy of +/- 1 ℃, supports automatic temperature control function and stepless speed regulation of 0~ 1500rpm, to meet the needs of multi-sample synchronous processing.

$ 569.00

Maximum stirring capacity 3 liters, stirring speed 200~ 1800rpm stepless speed regulation, Heating power 450W, Temperature range RT + 5~ 320 ℃, using aluminum alloy die-casting shell, high temperature corrosion resistance easy to clean.

$ 311.00

Heat collection heating method, heating speed and energy saving, Temperature range up to 300 ℃, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring.

$ 180.00

Single chip microcomputer control to achieve digital settings, with heating plate and liquid temperature double automatic temperature control, temperature control accuracy +/- 1 ℃, Max.stirring Capacity 10L, Speed range to 1500rpm, support 0-250 minutes timing.

$ 349.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.