Infrared Portable ThermoMeter

An infrared handheld thermometer converts the infrared radiation energy emitted from an object's surface into temperature readings. It is used for non-contact measurement of surface temperatures, such as monitoring temperature changes in paint drying and plastic processing.
Selection
When selecting, pay attention to the temperature measurement range covering usage requirements, the distance coefficient determining measurement accuracy, and the response time matching dynamic scenarios. Consider adjustable emissivity functionality and ambient temperature compensation, with the protection rating suiting on-site conditions.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

With a wide temperature measurement range of -50~ 480 ℃, the accuracy is +/- 1.5%, the Response Time is only 500ms, the object distance ratio is 12:1, suitable for fast non-contact measurement, lightweight and portable.

$ 103.00

Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.

$ 153.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.

$ 307.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.

$ 507.00

With -50~ 900 ℃ wide range and +/- 2% accuracy, 12:1 object distance ratio for non-contact measurement, Response Time 500ms, compact and lightweight only 170g, suitable for high temperature or hazardous environment.

$ 114.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast drying, low energy consumption and easy adjustment, suitable for a variety of Sample Handling.

$ 581.00

Ultra-small portable design can be put into the pocket, equipped with protective rubber cover to prevent falling; the use of a No. 5 battery can continuously measure tens of thousands of sets of data, that is, there is no need to wait for the test; the use of special microcomputer control to eliminate external light interference, to ensure 0.1% resolution High Accuracy measurement.

$ 444.00

Using Infrared source Nephilometry to reduce Color interference, automatic range conversion ensures accuracy, Measurement range 0.00-250 EBC, accuracy +/- 3% +/- 0.20EBC, built-in GLP function to store calibrated data.

$ 1100.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.