Incubator and Drying Oven

The dual-purpose drying and incubating chamber achieves drying and incubation functions through heating and humidity control. It is used for laboratory processes such as material curing and sample incubation, and in the coatings and inks industry for testing the drying performance of coatings.
Selection
When selecting, consider the temperature range and uniformity, humidity control accuracy, cabinet volume matching sample size, material corrosion resistance, and energy consumption indicators, and determine the parameter configuration based on specific experimental requirements.

Terms

Standards

Instruments

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.

$ 638.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ to +/- 1 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner easy to clean.

$ 761.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃, with forced warm air circulation to ensure uniform temperature, optional RS-485 interface to record temperature changes.

$ 971.00

Mirror stainless steel liner is easy to clean, Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ or +/- 1 ℃, with forced warm air circulation and timing function to ensure uniform and stable temperature.

$ 470.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, using mirror stainless steel liner and forced convection technology to ensure uniform temperature, four corners and a half arc easy to clean, the door opens automatically stop heating.

$ 1125.00

With dual functions of drying and fostering, temperature control accuracy of +/- 0.5 ℃, forced warm air circulation to ensure temperature uniformity, mirror stainless steel liner design for easy cleaning and maintenance, optional RS-485 interface for data recording.

$ 528.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 553.00

Application width 300mm, Spreader accuracy +/- 0.005mm, Drawdown blade can be quickly disassembled and cleaned, three independent temperature control oven to ensure uniform drying, suitable for a variety of substrates and Stock processing.

$ 24279.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Mirror stainless steel liner is easy to clean, temperature control accuracy of +/- 0.5 ℃, with forced warm air circulation to ensure uniform temperature, support 1-9999 minutes timing and over-temperature protection function.

$ 611.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Using forced warm air circulation to ensure uniform temperature, Temperature resolution of 0.1 ℃, equipped with microcomputer LCD controller temperature control is accurate, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.

$ 457.00

Cuboid Studio improves volume utilization, drying time is reduced by more than 40% compared with traditional Vacuum Chamber, Temperature range RT + 10~ 200 ℃, Vacuum Level up to 133Pa, double-decked Glass door is easy to observe.

$ 3896.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
The coating machine applies the adhesive layer of the plaster patch onto the backing layer.
The coating machine applies adhesive evenly onto the backing material through steps such as feeding, coating, drying, and winding, forming a stable adhesive layer.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Determination of dry matter content in pulp using an electric thermostatic drying oven.
This article introduces the method for determining the dry matter content of pulp using an electric thermostatic drying oven. Dry matter content is a key indicator for evaluating pulp quality. The principle of determination involves evaporating the moisture in the pulp through heating and calculating the content based on the mass difference before and after drying.
Zero-span tensile strength tester measures the tensile strength of wet pulp.
This article introduces the method of measuring the tensile strength of wet pulp using a zero-span tensile strength tester. Traditional testing is often conducted after the pulp is dried, but testing in the wet state can more directly reflect the bonding potential between fibers.
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
Drying Time Determination: Simultaneous Verification of Surface Drying Test Method, Through-Drying Test Method, and Instrumental Test Method
This article discusses three methods for determining the drying time of materials such as coatings. Traditional methods are divided into surface drying and through drying measurements, which are simple to operate but rely on subjective judgment. Instrumental methods provide objective data by monitoring physical changes such as mass and resistance, offering higher precision but at a higher cost.
Preparation of Paint Film Test Panels
The standardized preparation of paint film test panels is fundamental for accurately assessing the performance of paint films. The entire process includes key steps such as substrate selection and pretreatment, paint preparation, coating, drying and curing, thickness measurement, and curing.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The coating machine in the laboratory ensures a more stable functional layer on the surface of copper and aluminum foils.
The laboratory coating machine is used to apply functional layers on the surfaces of copper foil and aluminum foil. By precisely controlling parameters such as coating speed, slurry viscosity, and drying temperature, it enhances the uniformity and adhesion of the coatings.