Using high temperature dry heat technology, temperature control accuracy of +/- 1 ℃, rapid heating and over-temperature protection function, studio volume 70L, easy and safe operation.
Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.
Adopt high temperature dry heat technology, Temperature range RT + 10~ 250 ℃, Input Power 1550W, with High Accuracy Microcomputer LCD display, automatic over-temperature protection and forced convection design, shorten disinfection time.
Temperature uniformity is improved by fan speed control, the independent air duct circulation system automatically discharges water vapor, the dry culture mode is automatically converted, the temperature control accuracy fosters +/- 0.5 ℃, drying +/- 1 ℃, and the double door structure insulation does not affect the temperature in the box.
Adopt fan speed control to improve Temperature uniformity, automatic discharge of water vapor, automatic conversion of dry culture mode, temperature control accuracy of +/- 0.5 ℃, Timer Range 1-9999 minutes.
The friction speed is adjustable from 21 to 106 rpm, and the friction load is 908g or 1810g. It supports a variety of test modes such as dry grinding, wet grinding, and decolorization changes. The automatic shutdown function ensures accurate control of the number of tests.
With dry grinding and wet grinding dual test function, friction Frequency four-speed adjustable (21/42/85/106cpm), support 0~ 99999 automatic shutdown, in line with JIS-5071-1 and other standard requirements.
Measurement range 0-1000N penetration resistance, detection depth of 30 cm can be extended to 1.5 Meters, without the ring knife method can quickly obtain dry density data, complete the detection within 10 minutes.
With four-speed Adjustable Friction Frequency (21-106cpm), support 2lb/4lb friction load, can complete dry grinding, wet grinding, decolorization changes and other tests to meet a variety of standard requirements.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.
Using 200g weight and 1cm ² bottom area design, in line with GB/T 1728 standard, through the filter paper test method to accurately determine the film surface drying and practical drying time, easy to operate, reliable results.
Four-hole design with anti-dry burn protection, temperature control accuracy of +/- 0.5 ℃, 304 stainless steel liner to ensure durability, suitable for a variety of temperature sensitive experiments.
Double hole design with 330 × 180 × 140mm Tank, temperature control accuracy of +/- 0.5 ℃, 304 stainless steel liner to ensure durability, anti-dry burning protection to enhance experimental safety.
Imported stainless steel plate and circulating pump, Temperature Fluctuation ≤ +/- 0.5 ℃, Temperature range RT + 5~ 95 ℃, with anti-dry burning function, to ensure the safety and stability of the experiment.
Adopt high temperature dry heat technology, destroy microbial cell protoplasm by oxidation. Temperature range RT + 10-300 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and timing function, mirror stainless steel liner is easy to clean.