High-Low Temperature Tensile Tester

The high and low temperature tensile testing machine adjusts the test environment temperature through a temperature control chamber. It applies tensile force to the sample at the set temperature and measures the changes in the mechanical properties of materials at different temperatures. It is used to test parameters such as tensile strength and elongation at break of materials like plastics and rubber under high or low temperature conditions, making it suitable for product quality control and research and development testing.
Selection
When selecting, consider that the temperature range should cover the actual usage environment, the clamping method should match the sample shape, and the force range should be slightly greater than the material's maximum force. Temperature control accuracy affects data reliability, and the equipment must have temperature uniformity and safety protection functions. The operation interface should be simple, and maintenance convenience also needs to be evaluated.

Terms

Standards

Instruments

Using ball bearing drive and imported motor, Measurement accuracy up to +/- 1%, tensile speed 1-399mm/min adjustable, support sample size flexible adjustment and automatic data statistics function.

$ 2392.00

Using ball bearing drive and imported motor, Measurement range 0-30N accuracy of 0.01N, tensile speed 1-399mm/min adjustable, support sample size flexible adjustment and automatic data statistics.

$ 2392.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Test method to achieve tensile compression test, Accuracy grade 1, equipped with 7-inch touch screen display tensile curve, support 50 kinds of fixtures to meet more than 1000 material testing needs.

$ 3317.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

Adopt ball bearing drive and imported motor, with low noise and accurate control; 0~ 1000N force range, adjustable tensile speed from 1 to 399mm/min; support sample size flexible adjustment, with automatic reset and overload protection functions.

$ 2392.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 5947.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.

$ 6770.00

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.

$ 9352.00

Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.

$ 5431.00

Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.

$ 5560.00

Equipped with high and low temperature thermostatic cell, Temperature range 0-110 ℃, PT100 Probe real-time monitoring, liquid temperature can be corrected to ensure the accuracy of test data.

$ 353.00