Electronic Digital Temperature Tester

The electronic digital temperature tester senses the temperature of an object through a thermocouple or thermal resistor and converts the signal into a digital display. It is used to measure temperatures in processes such as paint drying and plastic processing to ensure accurate process parameters.
Selection
When selecting, consider that the measurement range covers usage needs, accuracy meets process requirements, probe type is compatible with the measured medium, response speed matches dynamic temperature measurement scenarios, and the protection rating suits the on-site environment.

Terms

Standards

Instruments

DC motor to ensure that the operation of more than 10,000 hours, no noise vibration; Electronic temperature control accuracy High Response Fast, heating power 150W, Temperature range RT +~ 100 ℃.

$ 123.00

DC motor to ensure noise-free vibration-free operation, electronic temperature control accuracy High Response, support 0-9999 minutes timing and 0-2000rpm speed regulation, heating power 400W to meet a variety of experimental needs.

$ 160.00

Quadruple Synchronous Stir Design, Temperature range RT +~ 100 ℃, using digital electronic temperature control technology, heating power 150W * 2, stirring speed 0~ 2000rpm, DC motor running without noise vibration.

$ 243.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, set of dispersion function and stirring function as one, adapt to different test needs.

$ 414.00

Six synchronous Stir design can process multiple samples at the same time, using electronic temperature control technology implementation RT +~ 100 ℃ accurate temperature control, stirring speed 0~ 2000rpm to meet the needs of different viscosity liquids, DC motor to ensure smooth operation without vibration.

$ 323.00

Adopt electronic constant force speed control circuit, digital direct display shaft Rotation speed, speed range 100~ 8000rpm, maximum processing viscosity 100000mPa.s, dispersion head generates swirl/spin tangential high line speed under high speed drive, through hydraulic shearing and high frequency mechanical effects to achieve efficient mixing, dispersion and homogenization.

$ 333.00

Set grinding, dispersion, stirring functions in one, using electronic speed line, digital display Rotation speed, Motor Power 400W, Lift Travel 200mm, suitable for a variety of experimental needs.

$ 670.00

DC brushless motor drive, torque up to 80mN · M, temperature control accuracy +/- 1 ℃, support table and liquid temperature dual control, electronic timing up to 9999 minutes, with dual digital display and intelligent PID temperature control function.

$ 412.00

Using microcomputer intelligent PID digital display temperature control, temperature control accuracy +/- 1 ℃, equipped with hot air circulation system to ensure uniform temperature, indoor shelf height and quantity adjustable, easy access to different specifications of samples.

$ 288.00

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Double row four hole design to improve efficiency, temperature control accuracy of +/- 0.5 ℃, temperature fluctuation of only +/- 0.1 ℃, stainless steel corrosion resistance, electronic temperature control technology is stable and reliable, suitable for a variety of experimental heating needs.

$ 146.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and intelligent digital temperature control instrument to ensure temperature Stability and durability.

$ 393.00

With temperature and rotational speed dual digital display function, temperature control accuracy of +/- 1 ℃, using PID self-tuning and thyristor control, Max. stirring Capacity 2000mL, heating power 500W, Pottery and porcelain coated panels are resistant to corrosion and high temperature.

$ 667.00

Temperature control accuracy of +/- 1 ℃, Temperature range RT +~ 299 ℃, stainless steel studio water Tank, excellent corrosion resistance, digital display automatic temperature control, easy and reliable operation.

$ 414.00

With bidirectional timing stirring function, Max. stirring Capacity 3L, speed range 0~ 2600rpm, electronic temperature control to ensure stable operation, suitable for small volume sample precision processing.

$ 190.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.