Low-Temperature Electric Drying Oven

The low-temperature electric oven heats the air inside the box using electric heating elements and maintains the set temperature in conjunction with a temperature control system. It is used for sample drying, curing, and aging tests, and is suitable for laboratory applications such as paint curing and plastic heat treatment.
Selection
When selecting, consider that the temperature range must cover the experimental needs, pay attention to the corrosion resistance of the chamber material, check the temperature uniformity parameters, confirm that the temperature control accuracy meets standards, inspect safety protection features, and determine the volume size based on the sample dimensions.

Terms

Standards

Instruments

Microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, volume 136L, with hot air circulation system to improve Temperature Uniformity, support independent temperature limit alarm and optional programming function.

$ 749.00

Adopt hot air circulation system to ensure Temperature Uniformity +/- 2 ℃, support 1-9999 minutes timing control, with RS-485 communication interface optional, suitable for drying and sterilizing operations.

$ 333.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, stainless steel liner corrosion resistance, electric heating tube heating fast and uniform, intelligent digital display easy to operate.

$ 403.00

Adopt hot air circulation system and low noise fan, temperature control accuracy +/- 1 ℃, Temperature Fluctuation +/- 1%, studio shelf height and quantity adjustable, equipped with double-decked tempered Glass observation window.

$ 311.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, hot air circulation system consists of low noise fan and air duct, the height and number of shelves in the studio can be adjusted, double-decked tempered Glass observation window is convenient for observing samples.

$ 362.00

Temperature control accuracy of +/- 1 ℃, Temperature Uniformity +/- 2 ℃, with overheating alarm and timing function, low noise hot air circulation system to ensure uniform drying, optional RS-485 interface connection recorder.

$ 449.00

Adopt microcomputer intelligent PID digital display thermostat, Temperature range RT + 5~ 300 ℃, Temperature Accuracy +/- 1 ℃. The hot air circulation system consists of low-noise fans and air ducts, and the height and number of shelves in the studio can be adjusted, which is convenient for accessing samples of different specifications.

$ 554.00

Adopt microcomputer intelligent PID digital display thermostat, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%. The hot air circulation system consists of low-noise fans and air ducts, and the height and number of studio shelves can be adjusted to facilitate access to samples of different specifications.

$ 343.00

Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with low noise fan hot air circulation system, adjustable height and number of studio shelves, double-decked tempered Glass observation window for easy observation of samples.

$ 320.00

Adopt stainless steel liner and low noise hot air circulation system, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, Inner Chamber dimensions 450 × 450 × 350mm, shelf height adjustable for sample access.

$ 427.00

Temperature control accuracy of +/- 1 ℃ and uniformity of +/- 2 ℃, using low noise hot air circulation system directly drying objects, with over-temperature alarm and 1-9999 minutes timing function, support RS-485 communication interface to record data.

$ 415.00

Adopt low noise fan and air duct to form hot air circulation system, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%, Inner Chamber dimensions 1000 × 800 × 800mm, shelf height and quantity can be adjusted, equipped with double-decked tempered Glass observation window.

$ 741.00

Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%, equipped with independent temperature controller, hot air circulation system consists of low noise fan and air duct, indoor shelf height and quantity can be adjusted.

$ 343.00

Equipped with independent temperature controller to ensure safety, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%. The hot air circulation system consists of low noise fans and air ducts, and the height and number of studio shelves can be adjusted.

$ 1398.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.