High-pressure Steam Autoclave

The high-pressure steam sterilizer uses saturated steam to create a high-pressure, high-temperature environment inside a sealed container, causing microbial proteins to denature and lose activity. It is used for sterilizing laboratory utensils, culture media, and other items, and is commonly found in medical and biological laboratory settings.

Instruments

Irreversible discoloration records the highest temperature, accuracy +/- 1 ° C to +/- 4 ° C, four-speed temperature monitoring range 104-121 ° C, oil-resistant, water-resistant and steam-resistant, instant Response without power supply.

$ 93.00

Irreversible Color change for long-term temperature recording; Resistant to oil, water and steam; Temperature accuracy is +/- 1 ° C below 100 ° C and +/- 1.5 ° C from 100 ° C to 154 ° C; Self-adhesive design for easy use and storage.

$ 93.00

The line pressure range is 0.33~ 80N/mm, and the width of the pressing roller is 300mm, which can complete ordinary pressing, high-pressure pressing, smooth pressing and calendering experiments, and support a variety of blanket pressing tests.

$ 5399.00

Using high temperature dry heat technology, temperature control accuracy of +/- 1 ℃, rapid heating and over-temperature protection function, studio volume 70L, easy and safe operation.

$ 574.00

Adopting the principle of irreversible discoloration, the accuracy is +/- 1 ° C below 100 ° C, with 6 temperature grids from 65 ° C to 93 ° C, oil, water and steam resistance to ensure stable operation in harsh environments.

$ 93.00

The heating zone temperature is as high as 900 ° C or more, sterilizing only takes 5 to 7 seconds, the built-in Pottery and porcelain funnel can ash organic matter to prevent cross-contamination, intelligent algorithms prolong the life of the heating body and improve the operation safety.

$ 219.00

Temperature control accuracy +/- 1 ℃, rapid heating using forced convection design. With over-temperature automatic interruption function, the shelf can be moved to facilitate cleaning in the box, ensuring safe and convenient operation.

$ 720.00

Adopt high temperature dry heat technology, effectively destroy the microbial cell structure through oxidation. Temperature range RT + 10~ 200 ℃, temperature fluctuation is only +/- 1 ℃, with forced convection system to improve heating efficiency, Multiple Safety protection mechanisms to ensure safe operation.

$ 438.00

Using high elasticity standard rubber and denim for extrusion test, extrusion pressure 10-120kgf adjustable, Test speed 5-30 times/minute, to meet the requirements of YD/1539-2006 standard.

$ 1079.00

Temperature control accuracy of +/- 1 ℃, rapid heating and forced convection mode, equipped with over-temperature automatic interrupt function to ensure safe operation, studio volume of 50L easy to handle all kinds of items.

$ 522.00

Temperature control accuracy +/- 1 ℃, rapid heating using forced convection mode, over-temperature automatic protection function to ensure safe operation, shelf can be moved to facilitate cleaning and maintenance in the box.

$ 961.00

Heating zone temperature of 825 ℃, sterilizing only 5-7 seconds; compact and portable, built-in intelligent algorithm to extend the heating life, Pottery and porcelain funnel can ash organic matter to prevent cross-contamination.

$ 248.00

Center temperature up to 825 ℃, 5-7 seconds quickly sterilized, compact and easy to operate, built-in Pottery and porcelain funnel to prevent cross-contamination, intelligent algorithms to improve safety and service life.

$ 267.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.

$ 444.00

Articles

Arc Resistance Tester measures the arc resistance performance of resin surfaces.
The arc resistance tester is used to evaluate the ability of insulating materials such as resins to withstand high-voltage arcs on their surfaces.
High Pressure Accelerated Aging Tester Evaluation of Paint Resistance to High Temperature, High Humidity, and High Pressure Environments
This article introduces how a high-pressure accelerated aging test machine evaluates the durability of colored paint under high temperature, high humidity, and high-pressure conditions. The test machine simulates these conditions to accelerate the aging of the coating and observe whether issues such as discoloration or blistering occur.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.