Varnish Color Comparator

The varnish colorimeter determines color parameters by illuminating a varnish sample with a light source and measuring the difference between its reflected or transmitted light and that of a standard color chart. It is used for color quality control in paint production to ensure color consistency between batches, and is applicable in fields such as furniture and automotive coatings.
Selection
When selecting a varnish colorimeter, consider measurement accuracy, sample adaptability (such as liquids or films), ease of operation, brand reliability, and maintenance costs to match practical application scenarios such as laboratory or production line requirements.

Terms

Standards

Instruments

Equipped with 18 standard color scale solution, prepared according to GB/T1722-92 standard, using an inner diaMeter of 10.75mm Glass testtube, Color comparison is carried out in the Color Assessment Cabinet to ensure accurate measurement results.

$ 136.00

Provide 25, 40, 70, 100 four profile specifications, size 87x87x2.5mm, weight only 60 grams, Portable design is convenient for quick comparison and evaluation on site.

$ 505.00

Made of stainless steel, the range is 10~ 100μm, Division 10μm, Dimension 65 * 36 * 1.5mm, suitable for Paints, varnish and other Coating Coating thickness measurement.

$ 119.00

With 45 °/0 ° illumination and D65 Measurement light source, viewing angle of 10 °, support for multiple Color model conversion, weight of only 45g for portability, quality control and complementary color suggestions.

$ 380.00

Contains 1026 standard Colors, conforming to the National Standard for Architectural Color Representation Methods, displaying 6 color samples per page, suitable for architectural color selection and management.

$ 130.00

The Fan Color Chart contains 1825 semi-matte Colors, with a color sample size of 2.5x5cm. It provides multi-language auxiliary name translation, and the upgraded model adds 200 new colors, which is convenient for industry color standardization applications.

$ 296.00

With Φ 4mm and Φ 8mm dual measurement caliber, Repeatability Delta E * ab < 0.06, can store 100 sets of master standards, Measurement time only 0.5 seconds, support sub-color difference display and Color bias analysis function.

$ 1009.00

Provide uniform ink speed three adjustable 450 to 800rpm, color development speed three adjustable 12 to 25rpm, color development pressure range -20 to 80, support ordinary or UV ink roller, improve work efficiency and applicability.

$ 7658.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

Adopt 0/d illumination geometry, Repeatability Delta E ≤ 0.2, equipped with 7-inch touchscreen, support data storage and a variety of color systems, suitable for reflection color measurement.

$ 2268.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Matte design system Color, including 290 commonly used Colors, 5 color samples per page 3.1x5.0cm, convenient for industry color comparison and application reference.

$ 93.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

Articles

Drop Ball Method of Impact Testing Machine for Evaluating the Impact Resistance of Varnish
This article introduces the use of the falling ball method with an impact testing machine to assess the impact resistance of varnish. The method involves dropping a steel ball of specified weight from a predetermined height onto a test panel coated with varnish to observe whether the coating cracks or peels off, thereby evaluating its impact resistance.
Wet film thickness gauge measures the wet film thickness of varnish.
The wet film thickness gauge is a mechanical tool used to measure the thickness of liquid varnish coatings. It operates by rolling the gauge so that the tips of its teeth contact the substrate and leave marks. The thickness value is then obtained by the operator reading the scale of the first tooth that becomes coated with the varnish.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Muffle Furnace Ash Test Method for Determination of Inorganic Filler Residues in Varnish
This article introduces the method of using the muffle furnace ash test to determine the residual amount of inorganic fillers in varnish. The inorganic substances in varnish can affect the performance of the coating, making accurate determination of ash content important for quality control.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Buchholz indentation tester measures the indentation hardness of varnish.
The Buchholz indentation test is a method for measuring the indentation hardness of coatings such as varnishes. It involves applying a specific indenter to the coating surface under a standard load, and after unloading, the length of the residual indentation is measured. A longer length indicates lower hardness.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermogravimetric Analyzer for Determining the Solid Content of Varnish
The principle of determining the solid content of varnish using a thermogravimetric analyzer is as follows: when the sample is heated, volatile solvents and moisture evaporate, leading to a decrease in mass, while the remaining solid mass stabilizes. The solid content is calculated by comparing the initial and final mass ratios.
Adhesion Tester Pull-Off Method for Determining Adhesion Strength of Varnish
This article introduces the test method for measuring the adhesion strength of varnish using the pull-off method. It involves adhering test cylinders to the coating and substrate with adhesive, then vertically pulling them apart with an instrument to record the maximum pulling force and calculate the adhesion strength.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
The pendulum hardness tester tests the scratch resistance limit of varnish.
The pendulum hardness tester measures the hardness of varnish by observing the attenuation of the pendulum's swing on the coating surface, with faster attenuation indicating a softer coating. The scratch resistance of varnish depends not only on hardness but also on elasticity and toughness. Hardness testing sets the basic threshold for scratch resistance.
Comparative Study of Lovibond Colorimeter and Iron-Cobalt Colorimeter
The Lovibond colorimeter and the iron-cobalt colorimeter are two widely used visual color measurement instruments in the industrial field. Both are designed based on the principle of standard color comparison, yet they exhibit significant differences in their specific implementation methods and application standards.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.