Precision Air Blast Drying Machine

The precision blast drying oven circulates hot air through a fan to rapidly and uniformly dehydrate samples in a constant temperature environment. It is used for drying materials, heat treatment, and moisture determination in laboratories, and is suitable for sample pretreatment in industries such as coatings and plastics.
Selection
When selecting, consider the temperature range and uniformity, corrosion resistance of the inner chamber material, and the precision of airflow adjustment. Determine the volume and dimensions based on the characteristics of the samples, check safety protection and energy consumption indicators, and choose the appropriate model based on daily processing capacity.

Standards

Instruments

Temperature uniformity is improved by fan speed control, air duct circulation system automatically discharges water vapor, temperature control accuracy of +/- 0.5 ℃, equipped with independent temperature limit alarm and RS485 interface expansion function.

$ 1890.00

Inner Chamber dimensions 500 * 600 * 750mm, Volume 225L, Temperature Fluctuation +/- 0.5 ℃, using air duct circulation system to automatically discharge water vapor, improve Temperature uniformity, support RS485 interface connection recorder.

$ 1069.00

Adopt air duct circulation system to automatically discharge water vapor, Temperature Fluctuation +/- 0.5 ℃, large screen LCD display multiple sets of data, independent temperature limit alarm system to ensure safe operation.

$ 885.00

Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.

$ 1009.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.

$ 925.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.

$ 1474.00

Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, Inner Chamber dimensions 310 × 310 × 310mm, variable speed fan can adjust the air volume, large screen LCD display multiple sets of data, with paraMeter memory and over-temperature alarm function.

$ 832.00

Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.

$ 683.00

Adopt vertical double air duct vertical hot air circulation technology, Temperature Fluctuation +/- 1.0 ℃, studio volume 65L, equipped with turbine centrifugal fan blades and PID intelligent temperature control to ensure uniform temperature distribution and accurate temperature control.

$ 751.00

Adopt vertical double air duct vertical hot air circulation, temperature control accuracy +/- 1.0 ℃, Temperature resolution 0.1 ℃, with timing and over-temperature alarm function, turbine centrifugal fan blade with bottom drum and bottom heating to ensure Temperature uniformity.

$ 1719.00

1000L large volume design, Temperature uniformity up to +/- 0.5 ℃, equipped with air duct circulation system automatic discharge of water vapor and over-temperature protection function, support RS485 interface connection recording device.

$ 3057.00

Vertical double air duct vertical hot air circulation to ensure uniform temperature distribution, temperature control accuracy of +/- 1.0 ℃, equipped with large screen LCD display and independent temperature limit alarm system, support 1-9999 minutes timing function, effectively ensure the safe and stable operation of the experiment.

$ 3410.00

Vertical double air duct vertical hot air circulation to ensure temperature uniformity, temperature control accuracy of +/- 1.0 ℃, turbine centrifugal fan blade with the drum design, fan speed adjustable, studio mirror stainless steel easy to clean.

$ 1248.00

Adopt air duct circulation system to automatically discharge water vapor, excellent temperature uniformity, temperature control accuracy of +/- 0.5 ℃, support 1-9999 minutes timing, equipped with independent temperature limit alarm to ensure safe operation.

$ 1127.00

Vertical double air duct vertical hot air circulation design, high temperature uniformity, temperature control accuracy of +/- 1.0 ℃, studio volume 30L, equipped with turbine centrifugal fan blades and low noise blower, fan speed regulation, easy operation and maintenance.

$ 603.00

Articles