Porous Digestion Apparatus

The porous digestion apparatus converts solid samples into measurable liquids by heating and acid digestion. It is used for pretreatment in environmental, food, and other fields to facilitate subsequent elemental analysis.
Selection
When selecting, focus on the number of wells meeting sample volume requirements, temperature control range covering experimental needs, corrosion-resistant materials, comprehensive safety features, and compatibility with laboratory power specifications.

Terms

Standards

Instruments

Heat and corrosion resistant material, can digest 25 samples at the same time, Temperature Stability up to +/- 0.5 ℃, support 0-180 minutes timing and continuous digestion, with overheating protection and temperature alarm function.

$ 2302.00

Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.

Impedance of PHY Glass film less than 500MΩ, with porous PTFE liquid complex and silver ion trap reference system, support 0~ 130 ℃ wide temperature measurement, Response is fast and stain resistance is strong.

$ 264.00

Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.

Adopt digestion Colorimetric integrated tube design, detection limit of 0.02mg/L, support 125 ℃ closed digestion, built-in imported cold light source life of 100,000 hours, can store 4000 sets of data and support multi-mode power supply.

$ 2203.00

Using sealing high temperature digestion technology, equipped with imported high-luminance Illuminant and PID automatic temperature control system, digestion temperature accuracy of +/- 1.0 ℃, can process 16 water samples at the same time, Optical inspection stability is excellent.

$ 1355.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.

Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.

The instrument adopts PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure consistent digestion of the same batch of samples, equipped with abnormal alarm and double-decked insulation system.

$ 1219.00

Using sealing catalytic digestion and Colorimetry measurement, the measurement range is 5~ 2000mg/L, the repeability is less than or equal to 3%, and the batch processing of 12 water samples is supported, and the operation is simple and time-saving.

$ 1114.00

The separate design of digestion and determination does not affect the accuracy, COD digestion is completed in 15 minutes, 30 standard Linear dispersion and 199 sets of data can be saved, 4-16 water sample batches are supported, and IP65 waterproof and dustproof design is adopted.

$ 1366.00

25-Hole Design Improves Sample Handling Efficiency, Temperature Control accuracy up to +/- 1 ° C to Ensure Digestion Stability, 12-minute rapid warming to 165 ° C to shorten waiting time, Transparent Shield for easy observation of the experimental process.

$ 1009.00

Using sealing catalytic digestion technology, the measurement range is 5~ 2000mg/L, the repeability is less than or equal to 3%, the batch processing of 16 water samples is supported, and the PID automatic temperature control and data storage function are provided.

$ 1355.00

Adopt 165 ℃ thermostatic digestion and spectrophotometric detection technology, detection range 0~ 20000mg/L, support digestion Colorimetric integrated tube design, built-in rechargeable battery, can store 4000 sets of data and support a variety of transmission interfaces.

$ 2526.00

Using PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure the same batch of sample digestion effect, simple and efficient operation.

$ 2849.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
BET surface area analyzer evaluates the pore structure of ion exchange resins
This article introduces how to use a specific surface area analyzer to evaluate the pore structure of ion exchange resins.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Bauer-McNett Classifier Method and Fiber Fractionation Principle of Pulp Fiber Classifier
The Bauer-McNett classifier is a standard method that separates fibers by length and morphology through the sequential screening of pulp suspensions using sieves with different aperture sizes.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Porosity Control in the Preparation of Porous Coatings During the Blade Coating Process
Doctor blade coating is a wet coating technique widely used for preparing functional coatings, which involves uniformly applying a slurry containing solid particles (such as ceramics, polymers, or metal oxides) onto a substrate, followed by drying and heat treatment to form the coating.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.