Emulsion RheoMeter

An emulsion rheometer measures the deformation and flow characteristics of fluids under shear forces by applying controlled stress or strain, analyzing parameters such as viscosity and elasticity. It is used to assess the stability and adjust the processing of emulsions like coatings and inks, helping to predict product storage and application behavior.
Selection
When selecting an emulsion rheometer, considerations should include ensuring the measurement range covers the viscosity and shear rate of the target samples, the temperature control accuracy matches actual conditions, the ease of operation suits daily use, the data accuracy meets basic testing requirements, and the maintenance costs and sample compatibility align with the laboratory budget.

Terms

Standards

Instruments

Measurement range 0-1mm, Graduation 0.001mm, using Dial reading, probe diaMeter Φ 5mm plane, pressure 22kPa +/- 5kPa, simple and reliable structure, suitable for laboratory and field determination.

$ 267.00

Measurement range 0-1mm, Graduation 0.001mm, probe diaMeter 5mm plane design, portable handheld for rapid measurement in the workshop, in line with industry standards.

$ 251.00

Measurement range 0-12.7 mm, Graduation up to 0.001mm, using flat probe design to ensure accurate and reliable test data, suitable for all kinds of material thickness detection.

$ 509.00

Glass sensitive film is used to fully sense the pH value of the liquid. Measurement range is 0~ 14pH, applicable temperature is 0~ 80 ℃.

$ 330.00

Equipped with 7-inch Touchscreen, easy to operate, support stepless speed measurement and viscosity automatic conversion, measurement range 1~ 75000000mPa.s, gigabit network port to ensure fast and reliable data transmission.

$ 3244.00

The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.

$ 683.00

Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.

$ 11125.00

The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.

$ 683.00

The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.

$ 683.00

The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.

$ 683.00

The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.

$ 683.00

The rotor shear rate is 2.0N, the sample volume is only 100 μL, the applicable viscosity range is 500~ 1000000mPa · s, the accuracy is +/- 2% F. S, suitable for processing a variety of fluid samples.

$ 683.00

The shear rate is 13.3N, the sample volume is 24μL, the applicable viscosity range is 75~ 150000mPa · s, the measurement accuracy is +/- 2% F. S, and it is suitable for a variety of fluid tests.

$ 683.00

Shear rate 2.0N, sample volume 1700μL, applicable viscosity range 32-63000mPa · s, accuracy +/- 2% F. S, suitable for a variety of fluid measurement.

$ 683.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
The coating machine applies a moisturizing lotion retention layer on the surface of the nonwoven fabric.
This article introduces the process of applying a moisturizing lotion retention layer on the surface of non-woven fabric using a film coating machine.