Measurement range 0-1mm, Graduation 0.001mm, using Dial reading, probe diaMeter Φ 5mm plane, pressure 22kPa +/- 5kPa, simple and reliable structure, suitable for laboratory and field determination.
Measurement range 0-1mm, Graduation 0.001mm, probe diaMeter 5mm plane design, portable handheld for rapid measurement in the workshop, in line with industry standards.
Measurement range 0-12.7 mm, Graduation up to 0.001mm, using flat probe design to ensure accurate and reliable test data, suitable for all kinds of material thickness detection.
Glass sensitive film is used to fully sense the pH value of the liquid. Measurement range is 0~ 14pH, applicable temperature is 0~ 80 ℃.
Equipped with 7-inch Touchscreen, easy to operate, support stepless speed measurement and viscosity automatic conversion, measurement range 1~ 75000000mPa.s, gigabit network port to ensure fast and reliable data transmission.
The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.
Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.
The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.
The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.
The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.
The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.
The shear rate is 3.3N, the sample volume is 134μL, the applicable viscosity range is 150~ 300000mPa · s, and the measurement accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.
The rotor shear rate is 2.0N, the sample volume is only 100 μL, the applicable viscosity range is 500~ 1000000mPa · s, the accuracy is +/- 2% F. S, suitable for processing a variety of fluid samples.
The shear rate is 13.3N, the sample volume is 24μL, the applicable viscosity range is 75~ 150000mPa · s, the measurement accuracy is +/- 2% F. S, and it is suitable for a variety of fluid tests.
Shear rate 2.0N, sample volume 1700μL, applicable viscosity range 32-63000mPa · s, accuracy +/- 2% F. S, suitable for a variety of fluid measurement.