Test Muffle Furnace

The test muffle furnace generates high temperatures through resistance heating elements, and the inner wall of the chamber is lined with insulating materials to minimize heat loss. It is used for operations such as sample ashing, melting, and heat treatment, facilitating physical and chemical transformation processes under high-temperature conditions in the fields of chemistry and materials science.
Selection
When selecting, pay attention to the maximum temperature to cover experimental needs, and ensure the furnace size matches the sample capacity. Consider the heating rate and control accuracy, as the type of thermocouple affects the temperature measurement range. The furnace door structure relates to sealing, and material corrosion resistance extends service life. Ensure the power specifications are compatible with laboratory conditions.

Terms

Standards

Instruments

The maximum temperature is 1200 ° C, the Furnace volume is 16L, and the 30-segment programmable control is used to achieve precise temperature control. The safety switch of the Furnace door and the design of the corrosion resistance Furnace improve the operation safety and durability.

$ 1716.00

With 30-stage programmable control function, the maximum temperature is 1000 ℃, the Furnace volume is 2L, the refractory brick Furnace and stainless steel material are used, and the heat loss is small and the Temperature uniformity is good.

$ 927.00

The highest temperature up to 1000 ℃, Furnace volume 16L, the use of refractory brick Furnace and wirecoil for heater heating, with automatic safety switch and overheating and overpressure protection, Furnace door sealing good heat loss is small.

$ 1145.00

With 30 programmable control function, the maximum temperature can reach 1000 ℃, Furnace volume 7L, automatic power-off protection when opening the door, good sealing of the Furnace door and small heat loss.

$ 1046.00

With 30 programmable control function, support heating or stay setting, stainless steel Furnace door and microcomputer PID controller, to ensure accurate and reliable temperature control, Furnace Temperature uniformity.

$ 1313.00

The maximum temperature is 1000 ℃, the Furnace volume is 30L, the 30-segment programmable controller is used to realize automatic operation, the Furnace door sealing is good to ensure Temperature uniformity, the refractory brick Furnace and the resistance wire heating element are resistant to high temperature and have a long life.

$ 1815.00

The maximum temperature can reach 1200 ℃, Furnace volume 7L, using microcomputer PID controller precise temperature control, refractory brick Furnace durable, Furnace door sealing design to enhance Temperature uniformity, safe and simple operation.

$ 1145.00

Double-decked Furnace shell insulation design to ensure that the shell is not hot, multi-sided Heating mode to make the Furnace temperature distribution uniform. Temperature control accuracy +/- 2 ℃, heating rate ≥ 10 ℃/min, equipped with K-type Thermocouple and a number of Safety protection functions.

$ 1582.00

Double-decked insulation Furnace shell to ensure that the shell is not hot, Furnace temperature distribution uniform, heating rate ≥ 10 ℃/min, with over-current, over-pressure, over-temperature and other multiple Safety protection, temperature control program can be customized settings.

$ 1227.00

The double-decked Furnace shell insulation design is adopted, and the shell is not hot; the Furnace temperature distribution uniformity is less than +/- 5 ° C, and the heating rate is ≥ 10 ° C/min; it has a nitrogen filling device to slow down oxidation and supports flexible setting of self-made temperature control programs.

$ 1019.00

Using ceramic fiber Furnace and air insulation structure, the surface temperature is only about 50 ℃. Heating to 1200 ℃ for less than 25 minutes, temperature control accuracy +/- 1 ℃, support multi-step program control.

$ 2048.00

With 30 stages of multi-stage programmable control, the highest temperature 1200 ℃, Furnace volume 7L, using refractory brick Furnace and nickel-chromium wire heating elements, heat loss is small and Temperature uniformity is good.

$ 1392.00

High aluminum Furnace wear-resistant high temperature, 4-sided heating evenly; PID self-tuning temperature control accuracy +/- 2 ℃, over-temperature automatic protection; compact overall structure, convenient and safe operation.

$ 567.00

Inlet and outlet devices are used to intRoduce inert gas to effectively prevent oxidation and decarburization of high-temperature heating workpieces. The Furnace volume is 16L and the maximum temperature is 1200 ° C. The high-temperature spraying process of the shell is durable.

$ 954.00

The refractory brick Furnace has good thermal insulation performance, volume 16L, maximum temperature 1200 ℃, temperature control accuracy +/- 2 ℃, with over-temperature alarm, power failure recovery and timing functions to ensure the safety and reliability of the experiment.

$ 1958.00

Articles

Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Impact of the Fixture Design of a Drop Hammer Impact Tester on the Plastic Impact Strength Results
This article primarily discusses the impact of the fixture design of a drop-weight impact testing machine on the results of plastic impact strength tests. The geometric parameters of the fixture, clamping method, and contact surface material can alter the stress state and energy transfer of the specimen, thereby affecting the accuracy of the test data.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.