Freeze-Thaw Test Chamber

The freeze-thaw test chamber simulates high and low temperature environments within a sealed space by using a compressor for cooling and electric heaters for heating. It is used to test the performance changes of materials under temperature variations, such as the cold resistance of coatings and the embrittlement point of plastics.
Selection
When selecting, ensure the temperature range covers the testing requirements, and pay attention to the heating and cooling rate specifications. The chamber volume should accommodate the sample dimensions, and consider the corrosion resistance of the inner chamber material. Check the temperature uniformity parameter and verify the validity of the equipment calibration certificate.

Terms

Standards

Instruments

Adopt -80 ℃ cold trap temperature and ≤ 5Pa Vacuum Level, support sample pre-freezing and freeze-drying of various containers, with one-button defrosting, data export and vacuum alarm functions, easy operation and easy maintenance.

$ 6281.00

Using silicone oil heating technology, the cold trap temperature can reach -80 ℃, Ultimate vacuum degree ≤ 2Pa, with sample pre-freezing function and color Touchscreen operation, support a variety of container freeze-drying needs.

$ 16759.00

Danfoss Compressor to achieve -60 ℃ low temperature, water capture up to 4kg/batch. With cold trap pre-freezing function without additional equipment, color Touchscreen display operating paraMeters, support data export and remote control.

$ 3974.00

Cold trap temperature can reach -80 ° C, Vacuum Level ≤ 5Pa, with sample pre-freezing function and color Touchscreen operation, support for a variety of container freeze-drying, built-in maintenance reminders and one-click defrosting.

$ 5242.00

Using sublimation principle to achieve material dehydration, cold trap temperature up to -60 ℃, Vacuum Level ≤ 5Pa, equipped with color Touchscreen and remote control function, support a variety of container freeze-drying operation.

$ 3743.00

Pure oil-free design ensures clean gas, exhaust volume of 1500L/min, automatic start and stop to reduce energy consumption, pressure dew point 2-10 ℃, suitable for a variety of industry needs.

$ 766.00

The stainless steel mirror heating Chamber and intermittent continuous heating technology are used to heat the sample evenly, with a heat-resistant temperature of more than 200 ° C. Equipped with HBM Sensor, it can remember multiple sets of drying processes and support three heating modes.

$ 612.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Adopt -80 ° C cold trap temperature and ≤ 5Pa Vacuum Level, with sample pre-freezing function and color Touchscreen operation, support data export and remote control, built-in maintenance reminders and one-click defrosting.

$ 6050.00

Cold trap temperature up to -70 ℃, Ultimate vacuum degree ≤ 2Pa, equipped with 7-inch Touchscreen display operating paraMeters, support data export and remote control functions, with one-button defrosting and vacuum alarm system.

$ 8142.00

The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.

$ 877.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level is 133Pa, the double-decked tempered Glass door is easy to observe, and the optional program control ensures the stoving conformity.

$ 3294.00

Articles

Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
5 Common Misconceptions in Selecting a Freeze Dryer: If Your Samples Are Damaged, You Probably Didn't Read This Article
Are you aware of the five common misconceptions when selecting a freeze dryer? This article highlights several pitfalls to help you avoid them.
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.