Laser Particle Counter

Laser particle counters operate by directing a laser beam through the gas being tested. The scattered light from particles is detected by a sensor and converted into electrical signals. Particle concentration and size distribution are then calculated based on the number and intensity of these pulses. These instruments are used in applications such as clean environment monitoring, air quality management, and process control.
Selection
When selecting, ensure that the particle size detection range and resolution match the sample characteristics. The sampling flow rate must meet the detection efficiency requirements. Consider the compatibility of the instrument calibration method and data output interface. Evaluate environmental tolerance and maintenance cycles. Verify compliance with industry standards.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

With six-channel particle size detection capability, Sampling flow rate 2.83L/min, using long-life laser Illuminant to ensure Stability, built-in thermal printer and support AC and DC power supply, can work continuously for more than 6 hours.

$ 1171.00

With six particle size channel detection capability, sampling capacity of 2.83L/min, built-in lithium battery supports 6 hours of continuous operation, using semiconductor laser Illuminant and color Touchscreen design.

$ 2510.00

100L/min Sampling flow rate and six particle size channel detection, equipped with long life laser Illuminant and imported air pump, support Touchscreen operation and USB data export function.

$ 10578.00

Using light scattering principle to detect 0.3-10 μ m particle size, Sampling flow rate 28.3L/min, built-in lithium battery supports 6 hours of work, can directly save data to U disk, equipped with thermal printer for on-site output.

$ 3922.00

Using 50L/min Sampling flow rate and six particle size channel synchronous detection, equipped with semiconductor laser Illuminant and Touchscreen control, built-in thermal printer supports real-time data output, Continuous Operating Time up to 5 hours.

$ 8461.00

With 6-channel synchronous detection capability, maximum sampling concentration of 35000 pcs/L, using semiconductor laser Illuminant life of 10 years, built-in battery life of more than 5 hours and support data export printing.

$ 1501.00

Using laser scattering technology, a single measurement can simultaneously display up to five particle size particulate matter (PM) concentrations, Sensitivity of 0.001 mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.

$ 4398.00

Using laser scattering technology, one measurement simultaneously displays five particle size data, detection range 0.01-100 mg/m ³, Sensitivity up to 0.01mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.

$ 4398.00

The stainless steel frame is suitable for wet and dry screening, laser engraving ensures clear traceability, and the aperture of 100μm meets the needs of fine grading.

$ 805.00

Featuring a stainless steel frame, suitable for dry, wet, and manual sieving, with a 500 μm aperture, laser-engraved labels provide clear identification and full traceability.

$ 604.00

Featuring a stainless steel frame suitable for dry, wet, and manual sieving, with a pore size of 250μm, laser engraving provides clear labeling to ensure full traceability.

$ 791.00

Adopting stainless steel frame, suitable for dry, wet and manual screening, with a aperture of 150 μm, laser engraved labels ensure clear traceability and meet ISO standards.

$ 604.00

Measurement range 0.5-3000 μm, maximum resolution 0.1μm, support more than 30 image analysis functions, Particle size distribution and morphology analysis.

$ 5237.00

The black background counting cell is used with annular fluorescent lamp side-shot illumination, and the colony contrast ratio is clear; the counter capacity is 0-999, and the inclined design of the cell surface is easy to observe, which can reduce the labor intensity of the experimenters.

$ 170.00

Articles