Using high frequency principle, the measurement range is 0-80%, the accuracy is 0.1/0, and the Response Time is 1 second. The probe type Sensor can penetrate deep into the material. The portable design weighs about 200 grams, which is suitable for on-site rapid detection.
Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.
Using resistance principle and temperature and humidity compensation technology, the measurement range is 0-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, and the portable design weight is about 203 grams, which is suitable for on-site rapid detection.
Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.
Conductivity Detector measurement principle, measurement range 0~ 84%, accuracy +/- 0.5%, Response Time 1 second, with temperature and humidity compensation technology, portable design weight only 265 grams, suitable for on-site rapid detection.
Using high frequency principle, Measurement range 0-99.9%, resolution 0.1/0, Response Time 1 second, portable design can be deeply measured inside the material, backlit LCD display is clear and low power consumption.
Temperature and humidity compensation technology to ensure accurate and stable measurement, Measurement range 0-84%, resolution 0.1%, Response Time less than 1 second, with MAX Maximum hold and automatic shutdown function, support a variety of data transmission interface customization.
Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.
Using resistance principle and temperature and humidity compensation technology, the measurement range is 3-80%, the accuracy is +/- 0.5%, the Response Time is 1 second, the portable and lightweight is only 203 grams, suitable for on-site rapid detection.
Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.
Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.
Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.
Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.
Ring quartz tungsten halogen infrared lamp is used for internal heating, with a unique temperature control system to achieve uniform heating, with 120g Capacity and 0.02% moisture readability, real-time monitoring of moisture changes and support for multiple sets of data storage.
Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.