Equipped with round water Bath cover and aluminum Cup body, flow hole diaMeter 5.6mm, capacity 50ml, in line with GB/T1723 standard, suitable for viscosity measurement.
The blade width is 100mm and the height is 60mm, and the Rod length is 300mm, generating tangential flow and high shear rate to prevent medium deposition, making it suitable for low-speed stirring.
Adopt 0.5% F.S. High Accuracy torque Sensor, support bi-directional torque test and 400 sets of Data storage, with locking force and opening force dual Measurement mode and peak hold function, to meet the needs of a variety of Encasement container testing.
Sampling speed up to 1920HZ, accuracy level 0.5, support three units of automatic conversion and a variety of test mode, with data storage and qualified judgment function, suitable for high-speed Impact torque detection.
Made of stainless steel, the slurry diaMeter is 50mm, the Rod length is 400mm, the mixing performance is mild, the tangential flow is generated during medium and low speed operation, the turbulence is small and the heat exchange effect is good.
The vacuum pressure plate is made of pure bronze, the drying temperature can be adjusted from room temperature to 120 ℃, equipped with double drying stations and intelligent drainage system, and the paper uniformity can reach 96.
With 1 level accuracy and +/- 1% Indication Error, it supports three test modes of real-time torque tracking, peak holding and first peak, and can store 99 sets of data and automatically calculate statistical values.
Mixing performance is mild, medium and low speed operation, the slurry diaMeter is 50mm, the Rod length is 300mm, the tangential flow is generated and the turbulence is small, and the heat exchange performance is good.
When stirring, a tangential flow is generated, and a high shear rate is formed at the edge to prevent medium deposition. The blade width is 100mm and the height is 60mm, and the Rod diaMeter is 8mm, which is suitable for low-speed and mild stirring.
The stirring performance is mild and suitable for medium and low speed use, the slurry diaMeter is 100mm and the Rod length is 500mm, and the tangential flow turbulence is small and the heat exchange performance is good.
Irreversible discoloration record the highest temperature, accuracy +/- 1.5 ℃, oil and water vapor resistance, instant Response, size 12 * 13mm round single grid design.
Electronic Sensor technology implementation 0.5 level accuracy, support three torque units automatic conversion, with peak hold and real-time tracking mode, can store 99 sets of data and automatically calculate statistical values.
Tooth spacing of 2mm, suitable for 0-60µm soft substrate, round cutter design with eight notches, effectively extend the service life, in line with ISO 2409 international standards.
The tangential flow is generated during stirring, the turbulence is small, the heat exchange performance is good, the slurry diaMeter is 50mm, and the Rod diaMeter is 8mm, which is suitable for medium and low speed mild stirring applications.
Made of stainless steel, the slurry diaMeter is 50mm, the Rod length is 350mm, the tangential flow is generated during stirring, the turbulence is small, the heat exchange performance is excellent, the performance is mild, and it is suitable for medium and low speed operation.