Adopt high-power high-illumination LED Illuminant, Color temperature adjustment range 2300K-8500K, illuminance adjustment range 0-3000LX, no stroboscopic design life of more than 10,000 hours, uniform illumination surface can flexibly adjust the position angle.
The uniformity of the transmission surface exceeds 90%, the standard four-speed Color temperature is adjustable, the illuminance adjustment range is 0-120000Lux, and the thickness dimming knob is equipped to achieve precise control. Illuminant has no stroboscopic and the lifespan is more than 10,000 hours.
Provide adjustable illuminance and Color temperature visible light, Color temperature range 2300K-8000K, illuminance up to 3000LX, infrared wavelength 850nm optional, radiation intensity greater than 400uW/CM ², stable light color without stroboscopic, life over 10,000 hours.
Using high-power LED Illuminant, Color temperature adjustment range 2300K-8500K, illuminance adjustment range 0-3000LX, life of more than 10,000 hours, uniform irradiation without stroboscopic.
Transmission surface uniformity of more than 93%, Color temperature adjustment range 2300K-8000K, Illuminance adjustable 0-160,000 Lux, Support Frequency adjustment 1-100KHz, life of more than 10,000 hours, can be connected through RS485 or WIFI computer control.
Imported Illuminant and narrowband filter system, Optical inspection stability, high accuracy; measurement range 0-1000mg/L, repeability +/- 2% F.S; Large screen Chinese display, easy to operate without Reagent.
High Accuracy Optical Path System to Ensure Measurement Correctness and Repeatability, Measurement range 0~ 6.000MCF, Zero drift +/- 1.5%, Support Multi-turbidity Unit Selection, Circuit Stable and Long Illuminant Life.
Adopt Android operating system, equipped with platinum ElectRode, support 1-3 point Automatic calibration, Measurement accuracy of 0.5% F. S, with automatic temperature compensation and Multi-ParaMeter simultaneous measurement function, 5.5 inch high definition touch screen easy to operate.
Measurement range of pressure -100 to 6000Kpa, temperature range -10-200 ℃, support 83 kinds of refrigerants, suitable for refrigeration system maintenance and fault diagnosis.
Imported long-life Illuminant and narrowband filter system, Optical inspection stability ≤ 0.002A/20min, measurement range 0~ 200mg/L, support users to calibrate Linear dispersion and long-term data preservation.
The built-in measurement system can be accurate to 1/100 micron, supports 1080P 60FPS video recording and a variety of geometric measurement functions, and the operation is simple and intuitive.
Using 100,000 hours long life Illuminant with narrow band filter system, Optical inspection stability is less than 0.002A/20min, equipped with 16-bit microcontroller to ensure stable performance, support users to calibrate Linear dispersion.
Measurement range 0.1-100 lx, accuracy +/- 3%, measurement of Flicker Frequency, Correlated Color temperature, Color rendering index, Blu-ray hazard ratio and other paraMeters, and display Spectral Curve.
Dual Probe design can measure two samples at the same time, equipped with BEPS low power error prevention system to avoid wrong readings, Measurement accuracy of +/- 0.5 ℃, support K/J/T type multiple temperature sensors, waterproof design to adapt to complex environments.
Using imported 100,000-hour long-life Illuminant with narrowband filter system, Optical inspection stability is less than 0.002A/20min, measurement range 0.001~ 0.500mg/L, support long-term data storage and user self-calibration.