Adopt 165 ℃ thermostatic digestion and spectrophotometric detection technology, detection range 0~ 20000mg/L, support digestion Colorimetric integrated tube design, built-in rechargeable battery, can store 4000 sets of data and support a variety of transmission interfaces.
Adopt digestion Colorimetric integrated tube design, detection limit of 0.02mg/L, support 125 ℃ closed digestion, built-in imported cold light source life of 100,000 hours, can store 4000 sets of data and support multi-mode power supply.
Colorimetric integrated tube design is adopted, with a detection limit of 0.5mg/L, high temperature digestion at 125 ° C, built-in 4000 data storage and a variety of transmission interfaces to meet the needs of on-site rapid detection.
25-Hole Design Improves Sample Handling Efficiency, Temperature Control accuracy up to +/- 1 ° C to Ensure Digestion Stability, 12-minute rapid warming to 165 ° C to shorten waiting time, Transparent Shield for easy observation of the experimental process.
16-Hole design to meet the needs of batch processing, 12 minutes rapid heating to 165 ℃, temperature control accuracy of +/- 1 ℃, equipped with a transparent shield for easy observation, support 5-999 minutes time adjustment.
Using sealing high temperature digestion technology, equipped with imported high-luminance Illuminant and PID automatic temperature control system, digestion temperature accuracy of +/- 1.0 ℃, can process 16 water samples at the same time, Optical inspection stability is excellent.
Heat and corrosion resistant material, can digest 25 samples at the same time, Temperature Stability up to +/- 0.5 ℃, support 0-180 minutes timing and continuous digestion, with overheating protection and temperature alarm function.
36-Hole design supports batch processing, temperature control accuracy of +/- 0.5 ℃, rapid heating to set temperature in 15 minutes, multi-point calibrating to eliminate measurement errors, standard imported glass tube anti-burst.
Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.
It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.
Colorimetric digestion integrated tube operation, no need to transfer liquid, Measurement range 0~ 250mg/L, detection limit of 0.5mg/L, multiple measurements of water samples to take the average value to reduce errors, suggesting detection of abnormalities.
Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.
Colorimetric integrated tube with digestion is used to realize detection integration, the detection limit is 0.01mg/L, Optical inspection Stability ≤ +/- 0.001A/20min, supports multiple power supply modes and wireless data transmission, and the portable design is suitable for on-site rapid detection.
Adopt digestion Colorimetric integrated tube design for safer and more convenient detection; minimum display value of 0.001mg/L, high Sensitivity; built-in rechargeable lithium battery, support long standby, power only 0.3W, strong portability.
Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.