Temperature Monitor

The temperature monitor detects changes in heat from objects through thermocouples or thermal resistors, converting temperature signals into electrical signals to display numerical values. It is used to record the temperature of environments, equipment, or materials, commonly found in applications such as ovens, reaction vessels, and storage scenarios, ensuring stable process conditions.
Selection
When selecting, consider whether the measurement range covers the usage scenarios, whether the accuracy matches the requirements, and whether the probe material is suitable for the medium characteristics. Pay attention to the response speed and data recording functions, check whether the protection rating is suitable for the environment, and confirm the calibration cycle and interface compatibility.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.

$ 89.00

The rated temperature is 55 ° C and the error is only +/- 1 ° C. The melting situation can be observed remotely, and it can be directly pasted for use in busbars or equipment terminals to monitor temperature changes.

$ 87.00

Adopting three-color reversible discoloration technology, when the temperature reaches 65 ° C, it changes from white to red, and after cooling, it turns to black to record historical overtemperature. The size of 25 * 40mm is easy to paste and install, and can be used repeatedly to monitor temperature changes.

$ 85.00

Adopt photometric 90 ° scattering measurement method, equipped with automatic cleaning brush and bubble measurement cell, support automatic sewage discharge and cleaning interval setting, Measurement range 0.00-500 NTU, Repeatability ≤ 2%.

$ 2783.00

Real-time monitoring of sample temperature, temperature range 0 ℃~ 100 ℃, accuracy +/- 1.0 ℃, can be used with a variety of Viscometers.

$ 119.00

With temperature discoloration warning function, when the temperature reaches 55 ℃ from black to red and display numbers, chill down Color reversible recovery, can be used to monitor temperature repeability.

$ 83.00

Temperature range 0~ 110 ℃, equipped with sample temperature detection device, can monitor and correct the liquid temperature in real time, to ensure that the test data is accurate and reliable, to meet the high requirements of the experimental environment.

$ 353.00

Rated temperature 60 ℃ accuracy +/- 1 ℃, can observe the melting state at a distance, directly paste the use without complicated operation, suitable for a variety of electrical equipment temperature monitoring.

$ 86.00

The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted and used without complicated operation, and is suitable for temperature monitoring of various electrical equipment.

$ 91.00

Temperature range -10~ 100 ℃, temperature resolution 0.01 ℃, with overheating and overcurrent multiple protection, large screen backlit LCD display, easy to operate and monitor.

$ 3323.00

Irreversible color change records the highest temperature, four-grid design can monitor multiple temperature points simultaneously, accuracy +/- 1 ° C to +/- 4 ° C, oil and water vapor resistance, instant Response for field application.

$ 106.00

The equilibrate temperature control method is used to achieve +/- 0.5 ℃ Temperature Fluctuation, Temperature Uniformity ≤ + 2 ℃, and the large-area observation window can monitor the sample status in real time to meet the strict environment testing requirements.

$ 3822.00

Adopt fully enclosed environmental protection Compressor refrigeration system, Temperature range -40~ 100 ℃, temperature resolution 0.01 ℃, with overheating and overcurrent multiple protection, large screen backlight LCD display is clear, easy to operate and monitor.

$ 5027.00

With pH, conductivity, TDS and temperature Multi-ParaMeter measurement, pH range 0.0-14, EC range 0-3999 μS/cm, supports Automatic calibration and continuous monitoring, waterproof design and large screen display for easy operation.

$ 538.00

The six-channel design supports multi-position simultaneous temperature measurement, Sampling rate of 0.05 seconds, with 512M memory can store 16 consecutive test data, and the heat insulation box works stably for 10 minutes in a 280 ° C environment to ensure the accuracy of high temperature scene data.

$ 1427.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.