Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control accuracy +/- 1.0 ℃, humidity control deviation +/- 3% RH, equipped with independent temperature limit alarm system, support 100 sets of programs 1000 cycle steps to ensure the stability and safety of the test process.
Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and 100 group program storage function.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.
Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.
Using multi-stage programmable PID controller, Temperature range -20~ 100 ℃, with independent temperature limit alarm system and P.I.D automatic calculation function, to ensure accurate and stable control of heat preservation Humidity, safe and reliable.
Humidity Control Range 35-95% RH, Input Power 8050W, Fluorine-free design, multi-stage programmable PID controller and imported 304 mirror stainless steel liner, with independent temperature limit alarm system.
Temperature range -20~ 100 ℃, Temperature resolution 0.1 ℃, using TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuations, with 100 sets of program capacity and a variety of Safety protection functions.
Fluorine-free environmental protection design, Temperature range 10~ 85 ℃, Temperature Fluctuation +/- 1 ℃, with multi-stage programmable PID control and independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.
Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.
Temperature range RT + 20~ 250 ℃, Fluctuation +/- 0.5 ℃, equipped with low speed swirl/spin turntable to ensure test uniformity, support multi-stage programmable control and ventilation regulation, easy data recording and fault diagnosis.
Temperature range -60~ 130 ℃, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export and remote monitoring functions.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 120 groups of programmable control and independent temperature limit alarm system to ensure safe and accurate testing.
Temperature range -20~ 130 ℃, Temperature Uniformity +/- 2 ℃, equipped with fluorine-free environmental protection refrigeration system, supports multi-stage programmable control, with independent temperature limit alarm and a variety of Safety protection functions.