Ultra-Low Temperature Water Tank

The ultra-low temperature bath uses a compressor refrigeration system and a low-temperature coolant circulation to lower the liquid inside the tank to temperatures below -40℃. It is used in scenarios requiring a stable low-temperature environment, such as low-temperature performance testing of materials, cryopreservation of biological samples, and thermal shock testing of electronic components.
Selection
When selecting, consider the temperature range and stability indicators to match experimental needs. Pay attention to whether the tank volume and opening dimensions are suitable for the sample size. Check the cooling rate and uniformity parameters. Ensure that the equipment's noise and heat dissipation requirements align with laboratory conditions. Confirm that safety protection features are comprehensive.

Terms

Instruments

Adopt ultra-low power consumption single chip standby for more than 6 months, imported high luminance Illuminant to ensure repeability +/- 1% F.S., IP65 protection and 0.01NTU resolution, support USB connection and data storage.

$ 800.00

Using ultra-low power consumption single chip standby for up to 6 months, equipped with imported high stability Optical inspection system to achieve +/- 1% F. S Accuracy, IP65 protection design to ensure harsh environment reliability.

$ 637.00

Suitable for ultra-low conductivity water sample measurement, Glass grinder liquid interface design, pH Measurement range 0-11, Temperature range 0-80 ℃, support can add liquid reference solution.

$ 273.00

Using ultra-low power 16-bit microcontroller, standby time can reach more than 6 months; measurement range 0~ 1000NTU, repeability +/- 2% F.S; Equipped with imported high-luminance Illuminant and cold Illuminant narrow-band interference Optical inspection system to ensure Optical inspection stability; Molded ABS case, IP65 design, anti-corrosion, waterproof and dustproof.

$ 664.00

Adopt stepper motor direct drive to ensure accurate speed, equipped with RTD temperature probe real-time monitoring, Measurement accuracy of +/- 1% F. S, with ultra-low viscosity adapter to extend Measurement range to 1mPa · s.

$ 1075.00

Measurement range 0-2μS/cm, suitable for ultra-low conductivity medium, support temperature compensation and a variety of installation scenarios to ensure Data Reliability.

$ 224.00

The lower limit of measurement can be up to 1mPa · s, the sample volume is only 30ml, the rotor is easy to load and unload and the running state can be observed, which is convenient for cleaning and detailed analysis of rheological characteristics.

$ 315.00

Viscosity range 0.6~ 6000000mPa · s, repRoducibility +/- 0.5% F. S, supports continuously variable speed and liquid crystal display of various paraMeters, suitable for ultra-low viscosity sample measurement.

$ 1255.00

Adopt 16-bit microcomputer processor and stepper motor drive to achieve continuously variable speed of 0.1~ 200rpm; standard L0 ultra-low viscosity adapter, only 25~ 30mL sample can accurately measure ultra-low viscosity, repRoducibility up to +/- 0.5% F.S.

$ 2110.00

Equipped with an ultra-low viscosity adapter, the viscosity test is as low as 1cp, the sample volume is only 25~ 30mL, repRoducibility +/- 0.5% F. S, Measurement +/- 1% F. S, support stepless speed control.

$ 1059.00

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.005 ℃, Temperature range covers -120~ 300 ℃, with low water level protection and alarm function.

$ 2061.00

Dedicated to 0.1~ 10mPa · s ultra-low viscosity liquid measurement, the sample volume is only 25ml, the cylinder rotor design can accurately calculate the shear rate, easy to sample detailed analysis.

$ 173.00

Microcomputer drive technology and imported stepper motor to ensure smooth speed, measurement accuracy of +/- 1% F. S, repRoducibility +/- 0.5% F. S, with automatic scanning function to help choose the right Rotor speed, with ultra-low viscosity adapter to support viscosity measurement as low as 1cP.

$ 659.00

Temperature Fluctuation +/- 0.005 ℃, Temperature Uniformity +/- 0.01 ℃, using non-heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, with low water level protection and alarm function.

$ 1300.00