Single point temperature measurement design, temperature point 70 ℃, irreversible discoloration characteristics, anti-fouling protective film design, specification 2.5x4 cm, service life indoor 3 years.
Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.
The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.
Six sets of independent digital PID temperature control system to achieve +/- 1 ℃ temperature control accuracy, dual cylinder design to ensure uniform pressure at both ends, Heat Seal Temperature range RT +~ 260 ℃, support layer setting can simultaneously test five sets of different paraMeter samples.
The vacuum environment can reduce the boiling point of the liquid and avoid the analysis of heat-sensitive substances; the independent temperature control laminate design realizes delamination temperature control; the stainless steel liner and the four-way heating system ensure Temperature uniformity of +/- 0.5 ℃.
Vacuum environment significantly reduces the boiling point of liquid, suitable for heat-sensitive substances; drying Temperature range RT + 50~ 200 ℃, Vacuum Level < 133Pa; inert conditions prevent oxide explosion, powder sample stability does not move.
Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.
The vacuum environment significantly reduces the boiling point of the liquid to below 133Pa, the temperature control accuracy reaches +/- 0.5 ° C, and supports independent temperature control of delamination; the stainless steel liner and the explosion-proof Glass door ensure the safe and efficient drying of heat-sensitive substances.
The vacuum environment significantly reduces the boiling point of liquids, handling heat-sensitive substances and preventing powder samples from moving. Temperature range is RT + 50~ 200 ℃, Vacuum Level is less than 133Pa, equipped with microcomputer intelligent control and double-decked explosion-proof Glass doors.
The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.
The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.
The vacuum environment effectively reduces the boiling point of the liquid and prevents the analysis of heat-sensitive substances; the Vacuum Level < 133Pa ensures efficient drying; the microcomputer PID control realizes accurate temperature control; the multi-layer independent heating system makes the temperature distribution more uniform.
Measurement range 0~ 2000ppm and automatic temperature compensation function, using external temperature sensor and Graphite electRode design, Response Time fast and accurate measurement, waterproof structure suitable for a variety of water quality environment detection.
Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.
Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.