High-Temperature Digital Rotary ViscoMeter

The high-temperature digital rotational viscometer drives the rotor to rotate in the sample via a motor, measures the fluid resistance, and directly displays the viscosity value. It is used to detect the flow characteristics of materials such as coatings and inks at high temperatures, guiding production process control.
Selection
When selecting, consider a temperature range that covers practical needs, rotor material that is corrosion-resistant, measurement accuracy that meets standards, an operation interface that is clear and easy to read, and a sturdy device structure suitable for workshop environments.

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Can measure the dynamic viscosity of normal temperature solid high temperature molten fluid, viscosity range 10~ 200000mPa · s, Temperature range RT +~ 250 ℃, repRoducibility +/- 0.5% F. S, support a variety of Rotor speed and timing functions.

$ 1476.00

Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.

$ 135.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 10~ 1000000mPa · s, temperature accuracy +/- 0.1 ℃, support continuously variable speed and direct liquid crystal display, no need for secondary calculation.

$ 1886.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 50~ 10000000mPa · s, temperature control accuracy +/- 0.1 ℃, support real-time monitoring of viscosity-temperature Linear dispersion and over-limit alarm function.

$ 2475.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 5~ 1000000mPa · s, Temperature control accuracy of +/- 0.1 ℃, support real-time display of shear rate and shear stress, out of range automatic alarm.

$ 2313.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range 400~ 80000000mPa · s, temperature accuracy +/- 0.1 ℃, support the whole process of monitoring viscosity-temperature Linear dispersion, suitable for solid to liquid substance measurement.

$ 2688.00

With a two-way temperature control system, the temperature can be raised to 50 ° C in -5 ° C environment, and the temperature can be cooled to 5 ° C in 32 ° C environment; the rotary oscillation mode is adopted, and the frequency range is started to 300rpm.

$ 1163.00

Rotation speed is accurate and stable with high subdivision stepper motor, the range covers 100~ 10000000mPa · s, supports continuously variable speed and +/- 0.1 ℃ accurate temperature control, built-in LCD liquid crystal directly displays viscosity, temperature and other Multi-ParaMeters, suitable for high temperature liquid sample measurement.

$ 2047.00

Temperature range RT +~ 60 ℃, Oscillation Frequency 0~ 300rpm, intelligent integrated circuit to achieve no drift temperature control, rotary oscillation mode to ensure uniform mixing.

$ 1219.00

Range 20~ 2,000,000 mPa · s, repRoducibility +/- 0.5% F. S, LCD display viscosity, Rotation speed, temperature and torque, easy operation and high accuracy.

$ 595.00

Rotation speed is accurate and stable, viscosity range is 50~ 10000000mPa · s, temperature accuracy is +/- 0.1 ℃, manual automatic measurement and stepless speed control are supported.

$ 2207.00

Using rotary oscillation mode, Oscillation Frequency 0~ 300rpm adjustable, temperature control accuracy +/- 1 ℃, with 5~ 120 minutes timing function, suitable for a variety of compounds thermostatic foster needs.

$ 548.00

Range 20~ 100000 mPa · s, with RTD temperature sensor can display sample temperature in real time, accuracy of +/- 0.1 ℃, support a variety of Rotor speed selection.

$ 440.00

Temperature range -20~ 100 ℃, cooling capacity 1200W, support high temperature direct drop technology, built-in pressure suction pump can withstand high temperature work of 80~ 300 ℃, with low liquid level protection and a variety of safety protection functions.

$ 2013.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.