COD total nitrogen total phosphorus analyzer

This instrument detects water samples through chemical digestion and photometry. COD is measured by oxidizing organic matter with potassium dichromate; total nitrogen is determined via UV spectrophotometry after alkaline potassium persulfate digestion; and total phosphorus is assessed through colorimetric measurement with ammonium molybdate. It is used for monitoring sewage and industrial wastewater, reflecting the degree of organic pollution and eutrophication in water bodies.
Selection
When selecting, consider whether the detection range covers common water quality standards, and ensure that the digestion temperature and time comply with national standard methods. Check whether it has an automatic calibration function and the stability of the supply of supporting reagents. Compare the detection accuracy errors of different models, and confirm the simplicity of the operation interface and maintenance cycle.

Terms

Standards

Instruments

With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.

$ 767.00

Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.

$ 4688.00

Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.

$ 3268.00

15 minutes to quickly heat up to the set temperature, temperature control accuracy of +/- 0.5 ℃, using multi-point calibrated to eliminate temperature errors, standard imported Glass digestion tube resistant to sudden cooling and sudden heating without bursting.

$ 522.00

36-Hole design supports batch processing, temperature control accuracy of +/- 0.5 ℃, rapid heating to set temperature in 15 minutes, multi-point calibrating to eliminate measurement errors, standard imported glass tube anti-burst.

$ 580.00

16-Hole design to meet the needs of batch processing, 12 minutes rapid heating to 165 ℃, temperature control accuracy of +/- 1 ℃, equipped with a transparent shield for easy observation, support 5-999 minutes time adjustment.

$ 925.00

Colorimetric integrated tube operation, no liquid transfer; measurement error ≤ +/- 5%, Repeatability ≤ +/- %; Support Multi-ParaMeter detection and post expansion, built-in thermal printer and 30,000 data storage.

$ 4430.00

25-Hole Design Improves Sample Handling Efficiency, Temperature Control accuracy up to +/- 1 ° C to Ensure Digestion Stability, 12-minute rapid warming to 165 ° C to shorten waiting time, Transparent Shield for easy observation of the experimental process.

$ 1009.00

Adopt digestion Colorimetric integrated tube design, detection is safer and more convenient; Minimum display value of 0.001mg/L, Sensitivity is high; Support standard measurement and continuous measurement mode, built-in 4000 sets of data storage, to meet different detection needs.

$ 3268.00

Colorimetric integrated tube design, supports more than 10 measurements to take the average value, measurement error ≤ +/- 5%, built-in 30,000 data storage and thermal printer, can expand the detection of ammonia nitrogen, total nitrogen and other paraMeters.

$ 2913.00

Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.

$ 4688.00

Measurement range 0.000~ 1.000mg/L, including 100mL molybdate solution, 25 packs of ascorbic acid powder and 25 packs of potassium persulfate powder, suitable for water quality total phosphorus detection.

$ 164.00

Colorimetric integrated tube design, sample digestion and result reading share a tube, no need to transfer liquid; more than 10 measurements of water samples and removal of abnormal values are averaged to reduce errors; built-in two COD detection methods, Measurement range 0-20000mg/L, detection limit as low as 2mg/L.

$ 3075.00

Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.

$ 164.00

Adopt digestion Colorimetric integrated tube design, no liquid transfer; support more than 10 measurements to take the average value, error ≤ +/- 5%; can store 30,000 data, compatible with 16mm and 25mm Colorimetric tubes.

$ 3430.00

Articles