ISO Standard Cup

The ISO standard cup is a cup-type viscometer used to measure the viscosity of liquids such as paints and inks. Its principle involves allowing the liquid to flow out from a small hole at the bottom and recording the time it takes to empty, which is then converted to viscosity. It is used for rapid on-site testing of fluidity and controlling product consistency during production.
Selection
Select the corresponding aperture model based on the viscosity range of the liquid being measured; choose stainless steel or plastic material considering material compatibility; verify the standard number to ensure compliance with ISO 2431; select mechanical or electronic type based on frequency of use; confirm that the temperature adaptation range matches the operating conditions.

Terms

Standards

Instruments

Measurement range 35~ 135cst, flow hole diaMeter 4mm, Benchtop design with bracket, in accordance with ISO2431 standard, suitable for viscosity testing.

$ 196.00

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.

$ 196.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.

$ 151.00

Adopting a double-sided design, the front supports No. 4 Cup and No. 2 Zahn Cup conversion, and the back supports ISO3-6, No. 3 Zahn Cup and Gardner Viscometer conversion, covering ISO2431, ASTM D4212 and other standards.

$ 256.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Using aluminum alloy Cup body and stainless steel filter, the outflow aperture of 3mm, 4mm, 6mm optional, Measurement range of 30~ 100 seconds, in line with international general viscosity test standards.

$ 238.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, the aperture is 5mm, and the viscosity measurement range is 91~ 326cSt, which is suitable for the determination of Newton-type liquid outflow time.

$ 146.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

It adopts aluminum alloy Cup body and stainless steel outflow nozzle structure, the outflow aperture is 6mm, and the outflow time of Newton-type liquid in the viscosity range of 188~ 684cSt can be measured, which meets the test requirements of international standards.

$ 146.00

Using titanium anodic oxidation aluminum material to ensure durability, 4mm filter design supports 34~ 135cSt viscosity test, conforms to ISO2431 standard, provides High Accuracy and repeatability, easy cleaning and maintenance.

$ 465.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 4mm, viscosity measurement range 34~ 135cSt, in line with international standards to ensure measurement accuracy.

$ 146.00