Rapid Color Difference Measuring Instrument

The fast color difference meter captures the reflected light from an object through photoelectric sensors, converts the color into digital signals, and compares them with standard color values to calculate color differences. It is used for color quality control in products such as coatings and plastics, ensuring color consistency between batches.
Selection
When selecting, consider matching the measurement aperture to the sample size, choose a model that includes the required color space indicators, confirm the instrument's repeatability error range, check the integrity of the calibration whiteboard, and evaluate whether the computer connection and data transfer functions meet operational requirements.

Terms

Standards

Instruments

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

Using 45 °/0 ° illumination, Repeatability Standard Deviation ≤ E * ab ≤ 0.08, can store 1500 sets of data, support a variety of Color difference formulas and four Available Light Sources to meet different measurement needs.

$ 501.00

With Φ 4mm and Φ 8mm dual measurement caliber, Repeatability Delta E * ab < 0.06, can store 100 sets of master standards, Measurement time only 0.5 seconds, support sub-color difference display and Color bias analysis function.

$ 1009.00

Equipped with eight Illuminants and three measurement diaMeters, the repeability accuracy reaches 0.05, supports a variety of Color difference formulas and display modes, built-in whiteboard automatic correction, suitable for irregular surface and small area measurement.

$ 1687.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

Using thermal printing technology, it is designed for use with testing instruments. It can directly connect the color difference Meter and Glossmeter to achieve real-time output of measurement data and report generation.

$ 220.00

Adopt 45/0 illumination light receiving system, 8mm measurement aperture, support single and average Measurement mode, Repeatability Standard Deviation ≤ E * within 0.1, can carry out color difference contrast analysis and color quality control.

$ 307.00

Equipped with eight Illuminant and eight Color difference formula, repeability accuracy of 0.05, support three display modes and 8mm general measurement aperture, built-in whiteboard automatic correction, suitable for a variety of materials Color measurement.

$ 1493.00

Adopt 8mm measurement diaMeter, Repeatability Delta E * ab < 0.05, equipped with TFT true color display, support a variety of Measurement light sources and Color difference formula, suitable for a variety of material surface color detection.

$ 1042.00

Using D/8 lighting mode and full Light spectrum LED Illuminant, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration and multi-function smart buttons, easy to carry and wireless connection, to achieve accurate Color measurement and Color Chart recognition.

$ 231.00

Measurement paraMeters can be continuously printed without connecting to a computer, and a variety of color difference Meter models are supported, which is convenient for on-site data storage and recording.

$ 186.00

Adopt D/8 lighting system and Φ 8mm measurement diaMeter, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with multi-function smart buttons and wireless connection function, support a variety of Color difference formula and chroma index measurement.

$ 312.00

Adopt 0/d illumination geometry, Repeatability Delta E ≤ 0.2, equipped with 7-inch touchscreen, support data storage and a variety of color systems, suitable for reflection color measurement.

$ 2268.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab within 0.1, support cloud database and popular color search, portable design battery life up to thousands of measurements.

$ 441.00

Featuring a 3.5-inch touchscreen for easy operation, it offers a measurement accuracy of 0.01 and a repeatability of ΔE*ab ≤ 0.03. Equipped with multiple built-in color cards for fast matching, it supports various color difference formulas and cloud-based data sharing.

$ 231.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Advantages of Barcol Hardness Tester in Rapid On-site Coating Hardness Testing
The Barcol hardness tester is a portable device suitable for rapid on-site measurement of coating hardness. It determines the hardness value by measuring the depth of penetration of the indenter, offering simple operation and test completion within seconds.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Cross-cut tester combined with adhesion test tape for evaluating coating peel-off.
The cross-cut test, paired with adhesion test tape, is a commonly used method for evaluating coating adhesion. It involves using a cross-cut knife to score a grid pattern on the coating surface, followed by the rapid peeling of specialized tape. The adhesion level is then assessed by observing the extent of coating detachment.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.