ZAHN Viscosity Cup for Laboratory

The Zahn viscosity cup in the laboratory determines viscosity by measuring the time it takes for a fluid to flow out through a small hole at the bottom of the cup. It is used to test the flow properties of liquids such as paints and inks, offering simple operation and suitability for on-site rapid testing.
Selection
Selecting a Zahn viscosity cup requires matching the viscosity range of the fluid being tested based on the cup number and its corresponding orifice size. Consider the material's corrosion resistance, as stainless steel is suitable for most solvents. Verify compliance with standard specifications, such as ASTM D1084, to ensure consistent testing conditions.

Terms

Instruments

Measurement range 400-1800cSt, equipped with 44ml Cup volume, correction factor 0.95-1, accurate viscosity test at 25 ℃ thermostatic environment.

$ 131.00

Portable design is easy to operate, volume 44ml, pore size 1.93mm, viscosity measurement range 5~ 60cst, outflow time 35~ 80s, suitable for rapid viscosity detection in the workshop.

$ 138.00

Filter diaMeter 2mm, viscosity measurement range up to 60cst, flow time 35-80 seconds, stainless steel durable and easy to clean, in line with international standards to ensure Measurement accuracy

$ 521.00

Filter diaMeter 4.3mm, viscosity measurement range 200-1200cst, stainless steel corrosion resistance, in line with international standards design, can quickly assess the liquid viscosity conformity.

$ 483.00

Immersion design, 2mm outflow aperture, viscosity measurement range 5~ 60cSt, stainless steel material, ASTM D4212 standard, correction factor 0.95~ 1.05.

$ 135.00

Aperture 4.26mm, viscosity measurement range 200~ 1200cSt, stainless steel corrosion resistance, portable immersion design for easy operation, correction factor 0.95~ 1.05 to ensure accuracy.

$ 131.00

Made of stainless steel, aperture 3.76mm, Measurement range 100~ 800cSt, correction factor 0.95~ 1.05, in line with ASTM D4212 standard, suitable for Newton type liquid viscosity test.

$ 131.00

Made of stainless steel, with a flow hole diaMeter of 2.74mm and a capacity of 44ml, it can accurately measure liquids in the viscosity range of 20-250cSt at 25 +/- 0.2 ℃ Ambient Temperature.

$ 131.00

Adopting a double-sided design, the front supports No. 4 Cup and No. 2 Zahn Cup conversion, and the back supports ISO3-6, No. 3 Zahn Cup and Gardner Viscometer conversion, covering ISO2431, ASTM D4212 and other standards.

$ 256.00

Made of stainless steel to ensure durability, the 2.7mm filter diaMeter is suitable for the viscosity range of 20-250cst, and the outflow time is controlled at 20-80 seconds. It is designed to meet ASTM standards to ensure measurement accuracy.

$ 478.00

Using stainless steel material, filter diaMeter 3.8mm, viscosity measurement range 100-800cst, outflow time 20-80 seconds, suitable for medium viscosity fluid rapid test.

$ 478.00

Made of stainless steel, filter diaMeter 5.3mm, viscosity measurement range 400-1800cst, can test high viscosity liquid, flow time 20-80 seconds, in line with international standards.

$ 485.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.