Elevated-Temperature & High-Pressure RheoMeter

The high-temperature and high-pressure viscometer simulates operating conditions through heating and pressurization to measure the flow resistance of fluids under specific conditions. It is used to detect viscosity changes of inks, coatings, etc., in high-temperature and high-pressure environments, guiding adjustments in production processes.
Selection
When selecting, it is necessary to match the temperature and pressure range of the material being tested, consider the measurement range and accuracy of the sensor, confirm the corrosion resistance of the sample cell material, inspect the safety protection functions of the equipment, and compare the temperature and pressure control stability of different models.

Terms

Standards

Instruments

The line pressure range is 0.33~ 80N/mm, and the width of the pressing roller is 300mm, which can complete ordinary pressing, high-pressure pressing, smooth pressing and calendering experiments, and support a variety of blanket pressing tests.

$ 5399.00

Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.

$ 11125.00

Measurement range of pressure -100 to 6000Kpa, temperature range -10-200 ℃, support 83 kinds of refrigerants, suitable for refrigeration system maintenance and fault diagnosis.

$ 254.00

Using high elasticity standard rubber and denim for extrusion test, extrusion pressure 10-120kgf adjustable, Test speed 5-30 times/minute, to meet the requirements of YD/1539-2006 standard.

$ 1079.00

Constant pressure ensures uniform sampling, suitable for a variety of powder material testing, implementation of GB9087-88 and other standards, improve sampling accuracy and conformity.

$ 222.00

The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.

$ 683.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

With automatic temperature compensation and air pressure compensation function, Measurement range 0.00-20 mg/L, accuracy +/- 0.30mg/L, support Data storage 450 group and Bluetooth printing, dustproof and waterproof grade IP54.

$ 591.00

Using R2.5mm steel ball to apply 20N pressure, test at standard temperature for 60 minutes and then evaluate the thermal deformation performance of the material through measurement of Crane diaMeter, which is suitable for testing of various electrical components.

$ 196.00

304 stainless steel material corrosion resistance, Operating Pressure up to 8kg/cm2, temperature measurement accuracy +/- 0.1 ℃, pot body rotation design makes the raw materials mix evenly, electronic control system brushless conductive to avoid common failures.

$ 4890.00

Irreversible discoloration design, temperature accuracy 50 ℃, circular single grid structure, specification 2x2cm, Pressure sensitive adhesive to ensure firm paste, suitable for temperature monitoring in harsh environments.

$ 88.00

The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.

$ 683.00

Manual pressure control pressure holding operation is simple, electronic pressure holding device reduces mechanical abrasion, pressure range 0~ -90kPa, accuracy +/- 0.1kPa, Organic Glass sealing barrel wall thickness 15mm to enhance compressive strength.

$ 887.00

Adopt 24-bit High Accuracy AD converter and stable pressure sensor, Measurement range 50~ 1400kPa, with full scale alarm and 3-speed limit protection function, support a variety of Unit switches and thermal printouts.

$ 1501.00

Tank volume 17L, Temperature range RT + 10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, equipped with maintenance-free pressure pump and multiple safety protection, support a variety of operation modes.

$ 875.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.