Ultrasonic thickness Gauge for metal

Metal ultrasonic thickness gauges utilize the principle of ultrasonic waves propagating and reflecting within materials, calculating thickness by measuring the round-trip time of the sound waves. They are used for detecting the wall thickness of metal pipes, containers, and other structures, finding applications in industrial maintenance and quality control.
Selection
When selecting, consider the measurement range, accuracy, and material type to ensure the instrument matches the metal being tested. Pay attention to probe size and temperature adaptability, check the calibration certificate and ease of operation, and choose between portable or fixed models based on the on-site environment.

Terms

Standards

Instruments

Using the principle of ultrasonic thickness measurement, Display resolution up to 0.01mm, with Probe zero point Adjustment, support Data storage and backlight display, can be used in dark environment.

$ 248.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Using dual crystal probe and ultrasonic pulse reflection technology, Measurement range 0.8-350 mm, the highest accuracy +/- 0.05mm, suitable for a variety of engineering materials, easy to operate.

$ 180.00

Measurement range 0.75-400 mm, accuracy +/- (0.1 + 1% H) mm, support standard and ultra-thin mode, built-in speed of sound of various materials, portable design for on-site inspection.

$ 173.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Measurement principle using ultrasonic pulses, accuracy of +/- (1% H + 0.1) mm, Measurement range 0.75-350 mm, with automatic zero point calibrate, two point calibrate and 200 data storage functions, support a variety of materials Speed of sound settings.

$ 251.00

Using ultrasonic measurement technology, Measurement range 0.75-350 mm, resolution up to 0.001mm, with anti-measurement sound speed function, can store 2000 sets of data, support a variety of probes to adapt to different working conditions.

$ 506.00

With 0.1mm high resolution and +/- 0.5% H accuracy, support single point 4 times per second and scan 10 times per second measurement frequency, adapt to rough surface and paint detection, with coupling status prompt function.

$ 687.00

Using microprocessor technology implementation 0.7-400 mm thickness measurement, resolution is +/- 0.01mm, support five Probe options, with automatic shutdown and backlight display function.

$ 577.00

Equipped with emission-echo and echo-echo two thickness measurement modes, can penetrate the coating measurement substrate thickness; Measurement range 0.65~ 600mm, accuracy +/- 0.05mm; Support Probe automatic identification and zero point calibrating.

$ 506.00

Measurement range 0.65-400 mm, the highest accuracy is +/- 0.04mm, supports four measurement modes, Data storage 3000 groups, high-speed measurement up to 10 times/second, suitable for a variety of metal materials.

$ 835.00

Using split Probe design, Measurement range 1.2~ 225mm, support anti-measurement Speed of sound function, Data storage and low voltage indication, suitable for a variety of material thickness measurement.

$ 175.00

Equipped with a professional timing chip, it offers a resolution of up to 0.001mm and a measurement range from 0.8mm to 800mm. With features such as gain switching, QC judgment, and automatic statistics, it is suitable for rapid and precise thickness measurement of various materials.

$ 312.00

Measurement range covers 0.8-350 mm, the highest accuracy is +/- 0.05mm, with 240 × 160 dot matrix LCD display, portable design weighs only 230g for field work.

$ 283.00

Measurement range of 1.5~ 200mm, error +/- (0.5% H + 0.2) mm, suitable for rough surface and paint measurement, support a variety of material thickness detection.

$ 243.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.