Infrared Dew Point Meter

The infrared dew point meter operates on the principle of gas absorption of infrared radiation to measure the moisture content in gases. It determines the dew point temperature by detecting the attenuation of infrared light at specific wavelengths. It is used to monitor the dryness of industrial gases, control humidity in processes such as compressed air and plastic drying, and prevent condensation or product quality issues.
Selection
When selecting an infrared dew point meter, consider whether the measurement range covers application requirements, the accuracy meets process standards, and the response time is compatible with process variations. Assess gas compatibility to avoid corrosion and consider the impact of environmental conditions such as temperature and pressure. Evaluate the ease of calibration and maintenance, and make a comprehensive judgment by balancing cost with long-term stability.

Terms

Standards

Instruments

Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.

$ 282.00

Built-in Probe design, surface temperature Measurement range -40~ 80 ℃, air temperature accuracy +/- 0.5 ℃, Humidity range 0~ 100% RH, providing stable and reliable dew point monitoring.

$ 677.00

Microprocessor control to ensure stability, measurement speed of 0.4 seconds, dew point range -20~ 40 ℃, small size and easy to carry, support automatic shutdown and backlight display.

$ 306.00

Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.

$ 1114.00

Measurement dew point range -40~ 40 ℃, Humidity 10~ 95% RH, automatic recording MAX Maximum, MIN Minimum and last value, Sampling time 0.4 seconds, easy to carry and strong structure.

$ 275.00

Measurement principle of cold mirror to eliminate system inertia error, accuracy of +/- 0.2 ° C, built-in electronic flowMeter to monitor 15-60L/h gas flow, system stability without repeability calibration.

$ 14371.00

Measurement accuracy up to +/- 0.2 ° C, built-in electronic flowMeter to monitor gas flow in real time to ensure stable and reliable measurement performance.

$ 2463.00

Quickly calculate the dew point through the wet-bulb temperature Measurement principle, support direct reading of relative humidity, integrated temperature unit conversion function, easy operation without complicated settings.

$ 240.00

Adopt DC electromagnetic control to achieve accurate ball drop, infrared point positioning to ensure drop accuracy, height adjustable range 0-1500mm, support 55g to 535g steel ball weight, equipped with data recording system to monitor Impact paraMeters in real time.

$ 367.00

Built-in Air Temperature Humidity Sensor and K-Connector, with armored cable and magnetic surface temperature sensor to prevent accidental detachment, supports a variety of optional Probe conversions.

$ 830.00

High Accuracy Sensor, Measurement range -40~ 40 ℃, Sampling rate 0.4 seconds, with MAX Maximum hold and automatic shutdown function, strong anti-interference for quick on-site detection.

$ 306.00

DC electromagnetic control ball drop, equipped with infrared pointing system to ensure accurate drop position, height adjustment range 0-2000mm, support a variety of steel ball weight selection, to meet the material anti-Impact performance testing needs.

$ 444.00

Built-in High Sensitivity Sensor ensures +/- 3% Humidity accuracy and +/- 0.5 ° C temperature accuracy, with 2500 data storage and USB transmission functions, robust protection design adapts to indoor and outdoor environments.

$ 1043.00

Simultaneous measurement environment Humidity and surface temperature, accuracy of +/- 0.5 ℃, storage of 20000 readings, support for a variety of K-type Probe extended measurement, with real-time graphics display and wireless transmission function.

$ 1716.00

High Accuracy Sensor for Multi-ParaMeter simultaneous measurement, Measurement speed up to 0.4 seconds, temperature error +/- 0.5 ℃, with backlight display and automatic shutdown function, portable design for on-site rapid detection.

$ 252.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.