Metal Tensile Force Gauge

Metal tension meters measure the force changes in materials under tension through sensors and display the readings on a digital screen. They are used to test mechanical properties of metal materials, such as tensile strength and yield point, and are commonly found in quality inspection departments and production lines.
Selection
When selecting a metal tensile tester, consider the maximum tensile range of the material being tested to ensure the capacity covers testing needs; pay attention to accuracy grade and calibration certificate; check fixture compatibility to accommodate samples of different shapes; confirm that data output interfaces match the recording system; and evaluate the durability of the device structure and ease of operation.

Terms

Standards

Instruments

Measured value 500N, suitable for rubber, cable, paper, electrical components, Plastic film and other materials tensile force, destructive force, insertion force test, supporting Force Gauge test bench.

$ 83.00

Measured value 15000N, suitable for bolt, screw and other standard parts of tensile strength test, designed for Force Gauge test bench, assist tensile testing.

$ 186.00

Measured value 500N, suitable for rubber, cable, paper, electrical components, Plastic film and other materials tensile force, destructive force and insertion force test, supporting the Force Gauge test bench.

$ 86.00

Measured value 500N, suitable for fabric, paper, wool, fiber, leather, rubber and other materials tensile force, destructive force and extension test, dedicated to supporting the Force Gauge test bench.

$ 101.00

Measured value 500N, suitable for all kinds of cable, Glass, leather, electrical components and other materials tensile force, destructive force, insertion force test, designed for Force Gauge test bench.

$ 89.00

Measured value 1000N, suitable for rubber, cable, packing tape, electrical components and other materials tensile force, destructive force, insertion force test, designed for Force Gauge test bench.

$ 93.00

Measured value 5000N, suitable for the tensile strength and destructive force test of steel wire, iron wire, fishing line, nylon wire rope and various cables with a maximum diaMeter of 6mm, specially designed for Force Gauge test bench.

$ 104.00

Maximum measurement value of 500N, dedicated to supporting the Force Gauge test bench for tensile testing, suitable for clothing button fixing parts strength testing and different button tensile testing.

$ 194.00

Suitable for a variety of material testing, Maximum Measured value 500N, can be matched with Force Gauge test bench for tensile testing, to meet the testing needs of different fields.

$ 89.00

Measured value 500N, suitable for tape, leather, clothing, rubber, electrical components, paper and other materials, assist Force Gauge in tensile testing to ensure test Stability and accuracy.

$ 143.00

This fixture is specially used to fix the Force Gauge display to ensure that the instrument is stable and does not shake during the test. It is suitable for a variety of Force Gauges to improve Test accuracy and ease of operation.

$ 138.00

Adopt gear pair drive, hand-pressed operation, rated load 500N, Travel 70mm, the upper and lower height of the frame can be adjusted, Force Gauge has a positioning structure, suitable for batch testing.

$ 256.00

It can be used with Force Gauge for vertical and horizontal testing, suitable for accurate measurement of thrust or tension, stable structure and easy operation.

$ 230.00

Measured value 500N, suitable for sheet, block material push-pull and destructive force test, can be used with Force Gauge test stand.

$ 130.00

Measured value up to 5000N, suitable for sheet and block material push-pull force and destructive force test, supporting the Force Gauge test bench.

$ 78.00

Articles

How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.