Wet Film Thickness Measurement Sheet

The wet film thickness gauge is a metal plate with a toothed structure, used to determine thickness by pressing it into the wet coating and observing the paint adherence on the tooth tips. It is employed for rapid monitoring of coating application quantities during construction, commonly used for on-site quality control in spraying and roller coating operations.
Selection
When selecting, ensure the measurement range of the gauge matches the thickness of the coating to be tested, and ensure the tooth-shaped structure is intact and unworn. Choose the appropriate material based on the viscosity of the coating, using stainless steel gauges for highly corrosive materials. Pay attention to ensuring the units of measurement on the gauge align with the construction requirements.

Terms

Standards

Instruments

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

Polygonal structure design, range 25~ 2032µm, in line with GB/T1764-79, GB/T134522-92, ISO 2808-74 standards, suitable for Paints, varnish and other Coating wet film thickness measurement.

$ 106.00

Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.

$ 119.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

Made of corrosion-resistant stainless steel, the thickness range is 250~ 700 μm, Graduation 50 μm, and fast and accurate wet film thickness measurement is achieved through the toothed structure.

$ 102.00

Made of corrosion-resistant stainless steel material, the thickness measurement range is 10~ 100μm, Graduation 10μm, and the toothed structure design can quickly read the wet Coating Film thickness to ensure measurement accuracy and conformity.

$ 102.00

Wire-wound design, wet film thickness 118.9μm, diaMeter 9.5mm, stainless steel material, wear resistance and corrosion resistance, suitable for preparing specific film thickness wet-film.

$ 167.00

Spreaders are formed to ensure uniformity, providing 36.6μm wet film thickness and 300mm application width. Stainless steel is durable and suitable for a variety of experimental studies.

$ 160.00

In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.

$ 127.00

Spreader 10 micron wet film thickness, 304 stainless steel material, easy to clean unbroken wire, provide customized services.

$ 157.00

Measurement range 0~ 12.7mm, resolution up to 0.001mm, contact pressure 20 +/- 0.5Kpa to ensure measurement Stability, suitable for all kinds of sheet material thickness detection.

$ 543.00

Using mechanical measurement method, Measurement range 0~ 1mm, accuracy ≤ 0.005mm, Graduation 0.001mm, probe diaMeter Φ 5mm, suitable for flat film and sheet, providing two probe pressure options.

$ 267.00

With 0.001mm High Accuracy and 1.0μm resolution, low pin pressure design and digital linear encoder, it supports multiple international standards for thickness measurement of various sheet substrates.

$ 20768.00

Using stainless steel material, application width 300mm, wet film thickness 77.7μm, film accuracy of 0.1 micron to ensure uniform film.

$ 160.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Operating specifications for on-site measurement of coating wet film thickness using wet film combs
This article introduces the operational standards for on-site measurement of coating wet film thickness using a wet film comb gauge. First, it explains the measurement principle of the wet film comb gauge, which involves estimating the thickness by observing the extent to which the teeth of the gauge are coated with the paint.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies an anti-reflection coating on the surface of optical lenses.
A coating machine is a precision device used for depositing anti-reflection coatings on the surface of optical lenses. Based on the principle of light interference, it forms a thin film of specific thickness on the lens surface through physical or chemical methods to reduce light reflection and enhance light transmission performance.
Wet film thickness gauge measures the wet film thickness of varnish.
The wet film thickness gauge is a mechanical tool used to measure the thickness of liquid varnish coatings. It operates by rolling the gauge so that the tips of its teeth contact the substrate and leave marks. The thickness value is then obtained by the operator reading the scale of the first tooth that becomes coated with the varnish.
Key Points for Wet Film Thickness Control in the Preparation of Fluorocarbon Coatings for Photovoltaic Backsheets Using Automatic Film Coating Machines
This article introduces the key points of controlling wet film thickness in the preparation of fluorocarbon coatings for photovoltaic backsheets using an automatic coating machine. Wet film thickness directly affects the performance and uniformity of the coating after curing, making its control crucial.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
The correct method for using a wet film thickness gauge.
The wet film thickness gauge is used to measure the thickness of uncured coatings. It determines the value by reading the scale through contact with the wet film using a toothed structure, which is crucial for controlling dry film thickness and estimating material usage.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
Control of Wet Film Thickness—Field Operation Comparison Between Wheel Gauge and Comb Gauge
This article compares two tools for measuring wet film thickness: the wheel gauge and the comb gauge. When selecting a tool, factors such as coating characteristics, application environment, and precision requirements must be considered. Additionally, proper operation and environmental influences should be taken into account to ensure coating quality.
Rapid Assessment of Paint Hiding Efficiency by Minimum Wet Film Thickness Method
This article introduces a method for rapidly evaluating the hiding efficiency of coatings—the minimum wet film thickness method. Traditional methods are time-consuming, whereas this approach quantifies hiding power by measuring the minimum wet film thickness required for the coating to completely hide the substrate, making it simple and quick to operate.
From aluminum foil and copper foil to electrode coating, the laboratory coating machine handles it all in one go.
A laboratory coating machine is a sample preparation device used for material research and development and quality control. It evenly applies slurry onto substrates such as aluminum foil and copper foil, forming a film of specific thickness by controlling the drying process.
The laboratory coating machine is used for perovskite battery research and development.
The laboratory film coater is a key piece of equipment in the research and development of perovskite solar cells, used for the precise preparation of perovskite functional layer thin films. By controlling parameters such as coating speed and blade gap, it influences the thickness and uniformity of the wet film, thereby determining the crystallization quality of the film and the final performance of the solar cell.