Coating Crosshatch Tester

The paint cross-cut tester creates a grid by cutting the coating, which is then peeled off with adhesive tape to observe the degree of coating detachment, thereby testing the adhesion strength between the coating and the substrate. It is used to evaluate the bonding strength of coatings and inks on metal and plastic surfaces, guiding adjustments in product formulations and verification of application processes.
Selection
When selecting, consider matching the cutting spacing to the substrate hardness; conventionally, a spacing of 1mm or 2mm is chosen. Handheld models are suitable for quick on-site testing, while benchtop models are ideal for precise control in laboratory settings. The number of blades should be selected according to standard requirements, typically 6 or 11 blades. An additional pressure adjustment function is available to accommodate coatings of varying thicknesses.
Tooth spacing
Number of teeth
Test substrate
Measured film thickness
Number of blades
Applicable standard
Miscellaneous

Terms

Standards

Instruments

Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.

$ 178.00

Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.

$ 120.00

Spreader 13 micron wet film thickness, application width up to 300mm, 304 stainless steel for durability and precise coating control.

$ 178.00

Adjustable application width, with automatic Spreader function, easy to operate, Repeatability is good, suitable for a variety of samples of laboratory prepative.

$ 4914.00

The extrusion production process ensures uniform coating, with a wet film thickness of 60μm meeting the demands of precise experiments. The 304 stainless steel material is durable and easy to clean, making it suitable for diverse coating performance tests.

$ 178.00

Using the formed pRoduction process, the wet film thickness is 6 microns, the accuracy is 0.5 microns, the cleaning is convenient and there is no worry of broken wire, to ensure the precision and durability of the coating prepative.

$ 120.00

Wound wire design, wet film thickness 125.7 microns, coating width 300 mm, stainless steel material ensures durability and precise coating effect.

$ 167.00

Using a wire-wound coating process, with a wet film thickness of 32.0 μm and a coating width of 300 mm, it is suitable for substrates prone to curling and convexity, enabling uniform wet film coating, with a wire diaMeter of 0.36 mm.

$ 167.00

Wet film thickness 29.7 microMeters, coating width 300 milliMeters, using stainless steel wire-winding process, suitable for experimental sample preparation.

$ 167.00

The punch is pushed to the test plate at a constant speed of 0.2 +/-0.1mm/s, and the thickness range of the test plate is 0.30-1. 25mm, which can detect the degree of coating cracking and is suitable for testing of various materials.

$ 1029.00

Formed design Coating Weight is about twice the wide-wound drawdown bar, wet film thickness 13μm, film accuracy of 0.5 micron, 304 stainless steel material to ensure durability.

$ 157.00

304 stainless steel material, wet film thickness 8 μ m, application width 300mm, formed pRoduction process to ensure uniform coating and continuous wire.

$ 178.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

The split structure is equipped with a dedicated thick coating Probe, Measurement range of 0~ 13000 μm, accuracy +/- 3%, IP65 Protection Rating and high-speed measurement capability of more than 60 readings per minute.

$ 1213.00

Utilizing a wire-wound process, the wet film thickness is 11.4 μm, with a diaMeter of 9.5 mm and a coating width of 300 mm. The stainless steel material ensures durability and precise coating results.

$ 167.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.