Graphite Digester

The graphite digestion apparatus generates uniform high temperatures by electrically heating graphite blocks, allowing samples and acids to undergo chemical reactions in a sealed environment to decompose organic matter or dissolve inorganic substances. It is used for laboratory sample pretreatment, converting solid samples into liquid form for subsequent testing, and is suitable for the analysis of heavy metals and trace elements in fields such as environmental science, food, and chemical engineering.
Selection
When selecting, consider matching the number of heating holes to the sample volume. Temperature control accuracy must meet method requirements, and corrosion resistance should accommodate common acid and alkali reagents. Heating speed affects processing efficiency, while safety features should include over-temperature protection and abnormal alarms. Maintenance should focus on the lifespan of graphite blocks and ease of cleaning.

Terms

Instruments

Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.

Using high purity graphite material and fuzzy PID temperature control technology, temperature control accuracy +/- 0.1 ℃, with over-temperature alarm, temperature self-setting and thermostatic timing function, panel size 400 * 300mm.

$ 808.00

Graphite electRode to reduce Polarization effect, automatic temperature compensation to ensure accuracy, Measurement range EC 0-3999μS/cm, TDS 0-2000ppm, resolution up to 1μS/cm, suitable for harsh environments.

$ 306.00

Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment needs.

Temperature control accuracy of +/- 0.1 ℃, using fuzzy PID control technology, with over-temperature alarm and temperature self-tuning function, heating material is high purity graphite, panel size 600 * 400mm.

$ 1332.00

It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.

$ 1927.00

Temperature control accuracy +/- 0.1 ℃, Temperature range RT +~ 450 ℃, using fuzzy PID control to achieve fast stability and small overshoot, with over-temperature alarm and self-tuning function, heating material is high purity graphite.

$ 912.00

PID microchip control to achieve +/- 0.5 ℃ temperature control accuracy, surrounded by heating to ensure that the temperature difference between holes ≤ +/- 1 ℃, high purity graphite heating material acid and alkali corrosion resistance, double-decked insulation design to improve safety and efficiency.

$ 1558.00

Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.

Using fuzzy PID temperature control technology, the temperature overshoot is small and the Stabilization time is fast; the temperature control accuracy reaches +/- 0.1 ℃, the panel size is 600 * 400mm; with over-temperature alarm and self-tuning function, to ensure the safety and accuracy of the experiment.

$ 1227.00

Using electric heating to directly generate high voltage steam, the highest Operating temperature 135 ℃ and accuracy of 0.1 degrees, with time temperature level control and automatic pressure chill down, 3 minutes after cooking items can be reduced to 20-40 ℃.

$ 3009.00

Temperature range RT + to 400 ℃, monitoring accuracy +/- 0.5 ℃, fast digestion and energy saving, suitable for a variety of sample pretreatment needs.

Using PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure the same batch of sample digestion effect, simple and efficient operation.

$ 2849.00

The instrument adopts PID microchip temperature control technology, temperature control accuracy +/- 0.5 ℃, temperature difference between holes ≤ +/- 1 ℃, surround heating to ensure consistent digestion of the same batch of samples, equipped with abnormal alarm and double-decked insulation system.

$ 1219.00