Using EPA custom Illuminant and chroma compensation technology, Measurement range 0.00-4000 NTU, minimum detection limit < 0.02NTU, support automatic range conversion and multiple calibrate modes to ensure the accuracy of low turbidity measurement.
High Accuracy Optical Path System to Ensure Measurement Correctness and Repeatability, Measurement range 0~ 6.000MCF, Zero drift +/- 1.5%, Support Multi-turbidity Unit Selection, Circuit Stable and Long Illuminant Life.
Measurement principle of 90 ° scattering light, Measurement range 0~ 200NTU, resolution 0.01, High Accuracy optical path system and stable circuit, support a variety of turbidity Unit switch, suitable for long-term stable operation.
The principle of scattered light is used for measurement turbidity, the measurement range is 0-200NTU, the resolution is 0.01NTU, the linearity is good and the operation is convenient, and it is suitable for a variety of water quality testing scenarios.
Measurement principle of 90 ° scattering light, Measurement range 0~ 50NTU, resolution 0.01, High Accuracy optical path system and stable circuit, support a variety of turbidity Unit switch.
Measurement principle of 90 ° scattering light, Measurement range 0~ 400NTU, resolution 0.01, indication Stability +/- 1.5%, support multi-turbidity Unit switching to ensure long-term reliable operation.
Measurement principle of 90 ° scattered light, Measurement range 0~ 20NTU, resolution 0.01, High Accuracy Circuit System and Long Life Illuminant, Ensure Measurement Correctness and Repeatability, Support Multiple Turbidity Unit switches.
Measurement principle of 90 ° scattering light, Measurement range 0~ 200NTU, resolution 0.01, High Accuracy optical path system and stable circuit, support for a variety of turbidity Unit switch, with print interface convenient data output.
Measurement principle of 90 ° scattered light, Measurement range 0~ 400NTU, resolution 0.01, High Accuracy Optical Path System and Stable Circuit, Support Multi-turbidity Unit switch, with print interface to ensure long-term reliable work.
Simultaneous measurement of turbidity, residual chlorine and total chlorine with EPA custom Illuminant, USEPA 180.1 compliant, automatic range conversion, turbidity Measurement range from 0.00 to 4000 NTU, support for multi-unit display and GLP data management.
Measurement range 0.00-1000 FTU, accuracy +/- 2 + 0.05FTU, average Measurement mode to ensure accuracy, GLP function to record data information.
Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.
With high and low turbidity ranges (0.00-9 and 100-1000NTU) and residual chlorine total chlorine measurement (0.00-5 mg/L), using EPA-specific Illuminant, supporting chroma compensation and Automatic calibration, storing 200 sets of data, suitable for a variety of water quality testing scenarios.
Measurement range 58~ 92% Brix, minimum reading 0.002, scale reading mode, compact shape only 155mm long, Net weight 160g for handheld operation, suitable for a variety of liquid concentration detection.
Optical inspection system to ensure long-term Stability, Stray Light and Color Interference to a low level, Measurement range 0-1200NTU, accuracy +/- 2% + 0.05NTU, support Manual calibration and GLP management functions.