Metal foil conductivity Meter

The metal foil conductivity meter applies current and measures voltage drop by contacting the surface of the metal foil with four probes, and calculates conductivity according to Ohm's law. It is used to detect the conductive performance of metal foil, monitoring product quality in industries such as electronic materials, packaging, and printing.
Selection
When selecting a metal foil conductivity meter, consider that the measurement range should cover the conductivity of the sample, the probe spacing should be suitable for the foil thickness, and it should be equipped with temperature compensation functionality. Pay attention to the instrument's calibration certificate and the wear resistance of the probe, ensuring ease of operation and compliance with industry testing standards.

Terms

Standards

Instruments

The stamping sampling method is accurate and fast, the limit cutting thickness range is 0.0045~ 0.1mm, and the sampling error is only +/- 0.01mm. The special treatment die blade is used, and it can be used for 2 years without replacement. It is suitable for high-fiber paper, metal foil and other materials.

$ 1848.00

The device uses 1200-1500lx Illumrination degree, achieves 80x magnification and 0.01mm resolution through scale Microscope, and can measure the maximum aperture of 2mm, suitable for aluminum foil pinholing light transmission observation.

$ 554.00

Measurement range 50~ 1400kpa, accuracy ≤ +/- 0.5%, using the method of Miao Lun, support paper, aluminum foil and non-paper sheet material detection, film convex disc pressure 9mm, upper and lower disc concentricity ≤ 0.25mm.

$ 964.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.

$ 741.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.

$ 208.00

Measurement range 0-2μS/cm with Mini-DIN 8 core connector for accurate detection of low conductivity solutions.

$ 199.00

Using Platinum Sensor to ensure linear stable measurement, Conductivity Detector cell constant K = 0.1, Glass shell corrosion resistance, suitable for 0~ 80 ℃ Operating temperature environment.

$ 206.00

Conductivity Detector 111800μS/cm@25 ° C with a capacity of 500ml provides accurate and reliable measurement of Conductivity Detector values, ensuring instrument calibrate accuracy and repeatability.

$ 127.00

Simultaneous measurement of conductivity, resistivity, TDS, salinity and temperature, support automatic temperature compensation and ElectRode diagnosis, Data storage 450 groups, with IP54 dustproof and waterproof rating, Measurement accuracy up to +/- 1.0% FS.

$ 514.00

Maximum load 50Kg, Test speed 10~ 60mm/min adjustable, using pointer sensing mode, effective Travel 0~ 360mm, suitable for vertical angle disbonding test.

$ 716.00

Measurement range 0.00μS/cm~ 100mS/cm, error +/- 0.5% F. S, temperature compensation coefficient 2%, LED display is clear, Stability is high, suitable for accurate conductivity detection.

$ 215.00

Providing 80,000 μS/cm@25 ° C standard Conductivity Detector values, the 500ml bottle is designed for easy laboratory operation, ensuring the accuracy and repeatability calibrated of the Conductivity Detector measuring instrument.

$ 127.00

Articles

Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Application of Roll-to-Roll Coating Machines in the Energy Storage Field
A roll-to-roll coating machine is a continuous coating equipment. Its core process involves uniformly applying slurry onto the surface of a flexible substrate (such as metal foil or polymer film), followed by steps like drying and rolling to produce continuous coated materials.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.