Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.
Aluminum alloy working platform and long life heating tube, Temperature range RT +~ 550 ℃, temperature error +/- 1 ℃, equipped with PID intelligent temperature Control system, can be customized heating Platform size according to demand.
Using copper plate working platform and long life heating tube, PID intelligent temperature control to achieve +/- 1 ℃ accuracy, Temperature range RT + 10~ 300 ℃, with automatic thermostatic function, easy to operate.
The 10x30mm standard size design ensures a perfect match with the SH1117 Tester, providing accurate gel strength measurement results.
Built-in temperature resistor real-time sensing sample temperature, gel KCL reference solution to ensure long-term stability of ElectRode, Measurement range 0~ 14pH, suitable for a variety of liquid environments.
Using Platinum Sensor and Gel KCL Reference Solution, Operating temperature range is 0~ 60 ℃ to ensure stable reference potential and good sensing ability.
Using plastic shell with 1 Meter BNC interface cable, specification is Φ 12mm × 120mm, built-in 3mol KCl gel reference solution without maintenance, Measurement range 0-14pH and 0-60 ℃, suitable for a variety of detection scenarios, providing stable and accurate acid alkalinity measurement.
Frequency adjustable continuously, stable operation and low noise, the device is suitable for gel treatment, molecular hybridization and X-ray film Development, etc.
Working Frequency 0-240rpm continuously adjustable, equipped with 340 * 250mm tray, support swing oscillation mode, low running noise and stable performance, suitable for gel treatment and molecular hybridization and other experimental scenarios.
Glass sensitive film fully sensing liquid or semi-solid pH value, gel KCL reference solution to ensure long-term use, built-in temperature resistance real-time sensing sample temperature, Measurement range 0~ 14pH, temperature resistance 100K.
Applicable to the flow time of not less than 20 seconds viscosity measurement, using aluminum material, capacity 50ml, flow hole diaMeter 5.6mm, can be converted into kinematic viscosity.
Glass sensitive film full sensing liquid pH, gel KCL reference solution to ensure long-term use, built-in 10K temperature resistor real-time sensing sample temperature, Measurement range 0~ 14pH.
Using quartz time base technology to ensure accurate measurement, Maximum Measured value 750N, Real-time display of tension data and support for voice prompts, automatic storage of upper and lower limit setting values, providing USB, RS-232 and Bluetooth Data output methods.
The bottom hole and tip design are adopted, and the outflow time is determined by observing the appearance of the tip, which realizes rapid viscosity measurement and is suitable for on-site testing needs.
The planar sensing structure can be directly bonded to curved and solid surfaces for measurement, with built-in 3mol KCl gel reference solution, Measurement range 0-14pH and 0-60 ℃, suitable for unconventional samples.