Industrial Temperature Monitoring Labels

Industrial temperature indicators operate based on the principle of thermochromic materials changing color when heated. When the surface of an object reaches a preset temperature, the indicator patch displays a color change. They are used to monitor equipment operating temperatures and verify the effectiveness of heat treatment processes. Commonly applied in scenarios such as temperature status checks for injection molds, drying equipment, circuit boards, and more.
Selection
When selecting, consider the compatibility between the material of the object being measured and the adhesive of the patch, observe whether the temperature range covers the usage requirements, confirm the clarity of color changes under ambient lighting conditions, check the correspondence between response time and process duration, and verify that product certifications comply with industry standards and requirements.

Terms

Standards

Instruments

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, adopts dual temperature Humidity compensation design, Response Time T90 ≤ national standard, with Internet of Things remote monitoring and a variety of Installation methods, suitable for complex industrial environments.

$ 317.00

With 4 grid temperature monitoring window, size 12x40mm, full sealing protective film design, with waterproof and oil-proof function, temperature recording is irreversible, Color change can not be restored to the original state.

$ 145.00

Support 1 or 2 point calibrated, Measurement accuracy +/- 0.5mg/L, with automatic temperature compensation and manual salinity pressure compensation function, can customize alarm limit and RS485 communication output.

$ 472.00

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, adopts pump suction and diffusion double Sampling method, has IoT remote monitoring function, Protection Rating IP66, Operating temperature range -40~ 55 ℃.

$ 1050.00

Using irreversible discoloration technology, the four-grid circular temperature monitoring range is 127 ° C to 143 ° C, with an accuracy of +/- 1 ° C. With oil and water vapor resistance, Response can instantly and permanently record the highest temperature.

$ 93.00

With 3 point button Adjustment, Measurement accuracy up to +/- 0.01pH, Support automatic temperature compensation and RS485 communication output, Custom alarm limit and a variety of function paraMeter settings.

$ 361.00

Record the highest temperature in history using irreversible discoloration technology, four-grid circular temperature monitoring range 149 ° C to 166 ° C, accuracy +/- 1 ° C to +/- 4 ° C. With oil resistance, water resistance and steam resistance, immediate Response and removal without delamination.

$ 96.00

Adopting stainless steel frame, suitable for dry, wet and manual screening, with a aperture of 150 μm, laser engraved labels ensure clear traceability and meet ISO standards.

$ 604.00

Adopt industrial PID self-tuning control technology, temperature control accuracy +/- 2 ℃, the highest temperature up to 1000 ℃, with over-temperature protection and automatic thermostatic Timing function, Furnace volume 7L, heating uniform and stable.

$ 412.00

Precision up to +/- 1 ° C error, can observe the melting state at a distance, visually display temperature changes, suitable for temperature monitoring of various electrical equipment connection parts.

$ 86.00

Supports simultaneous detection of 4 gases and integrated temperature and humidity monitoring, adopts dual temperature and humidity compensation design, with a visual distance of 10 Meters, a variety of wireless communication options and remote configuration functions, Protection Rating IP66, operation temperature range -40~ 55 ℃.

$ 727.00

Support up to 4 kinds of gas simultaneous detection, integrated temperature and Humidity monitoring function, with Internet of Things remote monitoring capability, dual temperature Humidity design to achieve physical and software double compensation, Protection Rating up to IP66.

$ 404.00

Support 4 kinds of gas simultaneous detection, integrated temperature Humidity monitoring, physical + software double revisit Humidity compensation, with zero automatic correction function, Response Time T90 ≤ national standard, detection accuracy ≤ +/- 3% FS.

$ 1050.00

Support 4 kinds of gas detection at the same time, integrated Humidity monitoring function, dual temperature Humidity compensation design, with 10 Meters visual distance high definition color screen, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 819.00

With unique discoloration and digital display function, it can change white to red, red to black three Color changes, temperature monitoring range of 75 ℃, can record over temperature history, with its own sticker for easy installation and use.

$ 86.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.