Circulating Constant Temperature Oil Trough

The circulating constant temperature oil bath maintains stable temperature within the bath through a heater for heating, a circulation pump to drive the flow of heat transfer oil, and a temperature sensor and controller. It is used for constant temperature heating of laboratory samples, material performance testing, and provides a uniform temperature environment in experiments such as paint curing and plastic aging.
Selection
When selecting, consider that the temperature range should cover the experimental requirements, the temperature control accuracy should match the testing standards, the tank capacity should accommodate the sample size, and the medium compatibility should prevent corrosion. Safety protection must include over-temperature protection, as the circulation flow rate affects heat transfer efficiency. Determine the oil type and power configuration based on actual working conditions.

Terms

Standards

Instruments

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface to meet the needs of complex experiments.

$ 12820.00

Imported stainless steel plate and circulating pump, Temperature Fluctuation ≤ +/- 0.5 ℃, Temperature range RT + 5~ 95 ℃, with anti-dry burning function, to ensure the safety and stability of the experiment.

$ 356.00

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity +/- 0.05 ℃, equipped with multi-level Safety protection device, optional program temperature control and Communication interface, to achieve accurate and stable temperature control.

$ 5173.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, support external circulation function and Flow rate 13L/min.

$ 1237.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.

$ 1317.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.

$ 1794.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices including low water level anti-dry burning and Compressor overload protection.

$ 6857.00

Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.

$ 3335.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and Communication interface.

$ 3226.00

Adopt non-heat centrifugal circulating pump to avoid self-heating affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control or magnetic stirring function to enhance application flexibility.

$ 1079.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.

$ 995.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices such as low water level anti-dry burning to ensure safe and reliable operation.

$ 1327.00

Adopt non-heat centrifugal circulating pump to avoid self-heating effect, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection devices, optional program temperature control and magnetic stirring system to enhance experimental flexibility.

$ 1093.00

Temperature range -50~ 100 ℃, accuracy +/- 0.02 ℃, equipped with imported Compressor and circulating pump, support multi-stage programming and data processing interface, with over-temperature alarm and liquid level protection function.

$ 3038.00

Articles

Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Fatigue testing machine evaluates the long-term durability of resin-based composite materials.
The fatigue testing machine is a key piece of equipment for evaluating the long-term durability of resin-based composite materials. These materials are widely used in fields such as aerospace, but their performance gradually degrades under cyclic loading.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.