Electrically Heated Magnetic Drive Stirrer

The electric heating magnetic stirrer drives the magnetic stir bar inside the container to rotate through the rotation of the bottom magnet, achieving liquid mixing, while the electric heating device heats the sample. It is used in laboratory operations that require heating and stirring, such as chemical reactions and solution preparation, ensuring uniform mixing and temperature control.
Selection
When selecting, consider the heating temperature range and precision, stirring speed range, material corrosion resistance, container size compatibility, and safety protection features. Determine the parameters based on the actual sample characteristics and operational requirements to ensure the equipment meets the experimental conditions and usage environment.

Terms

Standards

Instruments

Temperature range RT + 5~ 99 ℃, Temperature Fluctuation +/- 0.5 ℃, stainless steel liner, beaker hole can be arbitrarily changed in size, over-temperature sound and light tracking alarm to protect the sample.

$ 317.00

Max. stirring Capacity 1000mL, Speed range 0-1600rpm, using magnetic field drive technology implementation of non-contact stirring, suitable for a variety of low viscosity liquid mixing needs.

$ 107.00

Rotation speed is smooth and not affected by Power supply frequency, torque is 73.5mN · M, magnetic force is particularly strong, suitable for large capacity stirring, Max.stirring Capacity 20L, speed range 60-2000rpm.

$ 311.00

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Magnetic field drive technology implementation of liquid mixing, Speed range 0-1800rpm, Max. stirring Capacity 2000ml, equipped with 0-9999 minutes timing function, table size 130 * 130mm.

$ 104.00

Magnetic field drive technology implementation of liquid mixing, Speed range 0-1800rpm adjustable, maximum stirring capacity 2000ml, equipped with digital timing function, support charging and easy to move operation.

$ 115.00

Four or six station design, each station independent control, Max. stirring Capacity 1500mL, stirring speed range of 100~ 2000rpm, brushless DC motor to provide stable drive.

$ 378.00

Adopt magnetic drive technology, Speed range 0-1800rpm, Maximum stirring capacity 2000ml, Compact and portable, Support charging function, Operating voltage 12V, Suitable for a variety of low viscosity liquid mixing applications.

$ 110.00

Rotation speed is stable with brushless DC motor, torque is 73.5mN · M, magnetic force is especially strong, suitable for large capacity stirring, Max. stirring Capacity 20L, Speed range 60~ 2000rpm.

$ 323.00

ND servo motor drive, support 0~ 1250rpm stepless speed regulation and 5L large capacity Stir, with synchronous heating function, can accurately control the solution temperature, suitable for stable mixing of various viscosity liquids.

$ 186.00

Max.stirring Capacity 5L, stirring speed 0~ 2000rpm, using strong magnetic drive, suitable for medium capacity stirring, smooth and continuous operation.

$ 170.00

Driven by DC three-phase motor, Max. stirring Capacity 20L, Speed range 50~ 1800rpm, sturdy structure for continuous and stable operation, output power 40W to meet the needs of large capacity stirring.

$ 323.00

Rotation speed is smooth and not affected by Power supply frequency by brushless DC motor, Max. stirring Capacity is up to 20L, strong magnetic force and strong structure, high power voltage regulation output and Rotation speed and voltage display function.

$ 322.00

Driven by three-phase brushless DC motor, torque up to 100W, strong magnetic force, Max. stirring Capacity 50L, Speed range 60~ 1400rpm, suitable for large-capacity stirring, strong and durable structure.

$ 507.00

Using LCD and Button-Operated knob for easy operation, Nano Pottery and porcelain disc improve high temperature hardness and heat resistance Impact performance, support 0~ 1600rpm stepless speed regulation and 0~ 60 ℃ Temperature range, with independent safety circuit and temperature sensing monitoring.

$ 214.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.