Brass material Benchtop design, flow hole diaMeter 4mm, volume 100ml, in line with GB/T1723 standard, suitable for viscosity below 150s Coating detection, correction factor 0.97~ 1.03.
The 45 ° fixed angle design ensures precise application of 1000g constant pressure, coating marks are evaluated by 13 different Hardness pencil systems, and the four-link mechanism ensures test Stability.
Measurement range 0~ 2.5mg/L, resolution 0.01mg/L, Repeatability 1%, small size and easy to carry, reduce the use of personnel requirements, to provide reliable detection results.
Adopt back heating and horizontal forced convection design, Temperature Fluctuation +/- 0.5 ℃, Temperature range + 10 ℃~ 200 ℃, Sensor fault alarm and 9999 minutes timing function to ensure stable and efficient experiment.
Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.
Measurement range 35~ 135cst, flow hole diaMeter 4mm, Benchtop design with bracket, in accordance with ISO2431 standard, suitable for viscosity testing.
Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.
Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.
Measurement range 0.0~ 500μm, error +/- (0.3μm + 2%), ultra-small probe suitable for nails, bolts and other small workpiece thin platings measurement, with multi-point calibrating and statistical functions to ensure high Repeatability and Stability.
Measurement accuracy is increased by 96% with integrating sphere structure coating. Standard Deviation Delta E * ab ≤ 0.06 ensures Data Stability and supports a variety of chroma space and Illuminant selection.
Maximum load 0.5KN, designed for small force test, compact structure, easy operation, ensure test Stability and Repeatability.
Adopt 4mm small diaMeter design, accuracy of 0.1, 1.5 seconds fast measurement, support Automatic calibration and APP Data storage, equipped with ceramic whiteboard luminance value greater than 90.
Using swirl/spin design, light weight and easy to move, can effectively improve the Measurement accuracy and prevent the instrument from falling, suitable for small workpiece measurement scenarios.
Adopt imported accessories to ensure Stability, Blade Coating accuracy up to +/- 0.003mm, coating speed 5~ 200mm/s adjustable, effective coating area 400 * 400mm, improve film repRoducibility by controlling speed and pressure.
Impact energy 2.7mJ, Impact device mass 75g, small damage to the measured surface, does not damage the hardened layer, suitable for measurement of small and thin parts, the minimum thickness of the specimen is 1mm, and the minimum depth of the hardened layer is 0.2mm.