Capillary Tube Method Melting Point Apparatus

The capillary melting point apparatus determines the melting point of a substance by heating a sample capillary and observing the temperature at which the solid transitions to a liquid. It is used to assess purity and consistency and is commonly employed in the chemical and pharmaceutical industries for raw material testing.
Selection
When selecting, consider that the temperature range should cover the sample's melting point, and the heating rate should be adjustable. Pay attention to temperature control accuracy and observation methods to ensure ease of operation. Determine whether an automatic recording function is needed based on the characteristics of the sample.

Terms

Standards

Instruments

Microscope observation mode, support capillary method and hot table method, temperature range RT +~ 320 ℃, resolution 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), Draft Shield design to reduce environmental impact.

$ 749.00

Using binocular stereo Microscope observation, support capillary method and hot table method two measurement methods, temperature resolution of 0.1 ℃, repeability +/- 1 ℃ (≤ 200 ℃), with Draft Shield to reduce environmental impact.

$ 875.00

Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.

$ 624.00

With dual measurement function of capillary method and coverslip method, support eight linear heating rate of 0.2-5 ℃/min, Temperature range RT + to 320 ℃, resolution 0.1 ℃, can clearly observe the melting process of trace samples, suitable for dark, low purity and analysis samples.

$ 2015.00

With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.

$ 988.00

Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.

$ 1521.00

With 0.2~ 5 ℃/min eight linear heating rate control, Temperature resolution of 0.1 ℃, Support Capillary Method and Cover Slip Method Measurement mode, Can observe 40X~ 100X zoom sample melting process.

$ 2244.00

With 0.2-5 ℃/min eight linear heating rate, Temperature range RT + to 320 ℃, support capillary method and coverslip method two Measurement mode, can observe the details of the whole process of sample melting.

$ 3023.00

Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.

$ 2397.00

Using 30fps high-resolution video and 720P camera to observe the sample melting process in real time, support 0.1-20 ℃/min heating rate adjustable and four capillary tubing simultaneous processing, in line with pharmacopoeia specifications.

$ 4269.00

With five linear heating rate control, Temperature resolution of 0.1 ℃, support capillary method and coverslip method Measurement mode, high power microscopic observation is suitable for dark, low purity and analysis samples.

$ 859.00

Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.

$ 654.00

It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.

$ 3172.00

Using high-resolution digital camera for automatic detection and playback function, can simultaneously measure three capillary tubing, temperature control using platinum resistance to improve accuracy, with automatic and manual visual two measurement modes.

$ 4188.00

Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.

$ 4414.00