Rubber Doctor Blade Coating Machine

The doctor blade Coater evenly spreads the coating onto the substrate surface using a blade, controlling the coating thickness through mechanical pressure. It is used for surface coating treatment of materials such as paper and films, achieving quantitative coating and surface modification.
Selection
When selecting, consider the substrate type and width to match the scraper material and angle. Determine the coating speed based on the viscosity of the paint, and adjust the pressure according to the coating thickness requirements. Combine the drying method and production environment to select the appropriate equipment specifications.

Terms

Standards

Instruments

Using Metering Rod & doctor blade double Spreader mode, Spreader accuracy up to +/- 0.001mm, Spreader rate 5~ 200mm/s adjustable, fixed substrate by vacuum adsorption to ensure film uniformity and repRoducibility.

$ 2736.00

Spreader speed 5~ 180mm/s, Spreader area 400 * 300mm, using Metering Rod & doctor blade and vacuum adsorption system to ensure Spreader uniformity and Stability, can be customized automatic inking function.

$ 9755.00

Using Metering Rod & doctor blade dual Spreader method, Spreader accuracy is up to +/- 10μm, Film thickness range is 0-5000μm. Spreader rate and stroke are controlled by vacuum adsorption to fix the substrate, and the touch screen can effectively improve film repRoducibility and conformity.

$ 3462.00

Spreader accuracy of +/- 0.003mm, Film thickness range of 0~ 10mm, equipped with automatic feeding system and vacuum adsorption, to achieve stable Spreader and efficient operation.

$ 8949.00

Spreader accuracy of +/- 0.001mm and +/- 0.003mm respectively, support 5~ 200mm/s stepless speed change and vacuum adsorption fixation, improve coating conformity.

$ 7141.00

Utilizing a dual coating method with wire rod and doctor blade, the coating speed is adjustable from 1 to 300 mm/s with stepless speed control, ensuring high precision in film thickness control. Equipped with vacuum adsorption and heating functions, the temperature uniformity reaches ±1°C. The flip-top design facilitates easy cleaning.

$ 24279.00

Spreader speed 5-180mm/s adjustable, wire Rod Spreader accuracy +/- 0.001mm, using touch screen control and mechanical fixture to ensure stable and reliable Spreader process.

$ 2010.00

Blade Coating method, coating speed 1~ 500mm/s stepless speed regulation, wire speed accuracy +/- 1%, equipped with Vacuum chuck and heating function, clamshell drawdown blade design for easy cleaning, support application length and speed free adjustment.

$ 5883.00

With bar and drawdown blade two coating methods, coating speed 1~ 300mm/s stepless speed regulation, clamshell drawdown blade design for easy cleaning, bar accuracy of +/- 0.001mm, Blade Coating thickness range of 0.1~ 10mm, effective coating area 1500 * 300mm.

$ 7335.00

Spreader speed 5~ 200mm/s continuously variable speed, scraper Spreader accuracy +/- 0.003mm, support heating temperature RT +~ 180 ℃, baseplate heating method to ensure stable Spreader effect, improve experimental conformity.

$ 7658.00

Adopt clamshell type Blade Coating head design, easy to clean; coating speed 1~ 300mm/s stepless speed regulation, Spreader accuracy up to +/- 0.003mm, to meet the laboratory High Accuracy film needs.

$ 2978.00

With bar and drawdown blade two coating methods, Spreader thickness range 0~ 10mm, coating speed 5~ 200mm/s, support stepless speed and automatic feeding customization function.

$ 9755.00

With meyer Rod coating accuracy +/- 0.001mm and Blade Coating accuracy +/- 0.003mm, support Vacuum chuck and fixture fixing, coating table size 1440 * 1030mm, clamshell design is easy to clean.

$ 19438.00

Measurement range of 10-1000 μm with dual blade design, LED lighting Microscope and swirl/spin system to accurately assess substrate and coating defects, reducing computational requirements.

$ 299.00

Adjustable Blade Coating device to achieve 0.005-3mm thickness control, equipped with 200 ℃ heating roller and 1 Meter drying tunnel, support 1-10m/min continuous coating speed, with automatic correction function to ensure material alignment.

$ 19438.00

Articles

Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Comparison of Selection Between Dual-Column Gantry and Single-Column Universal Testing Machines for Plastic and Rubber Testing
This article compares the differences between dual-column portal and single-column universal testing machines in plastic and rubber testing. Dual-column portal types offer high rigidity and large load capacity, making them suitable for high-strength materials and high-precision testing; single-column types have an open structure and low cost, making them ideal for small loads and frequent fixture changes.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
The Printability Tester Simulates the Effects of Different Printing Pressures on Offset Ink Transfer Rate.
This paper investigates how the printability tester simulates the effect of different pressures on ink transfer rate in offset printing.
Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Rotating Rubber Wheel Abrasion Tester for Determination of Coating Taber Abrasion Index
This article introduces the method for determining the Taber abrasion resistance index of coatings using a rotating rubber wheel abrasion tester.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.
Shore hardness tester measures the hardness of rubber sealing rings.
This article introduces the method of measuring the hardness of rubber sealing rings using a Shore durometer. The Shore durometer presses a needle into the rubber surface under spring force and converts the indentation depth into a hardness value, commonly using the A scale.
Rubber non-rotor vulcanization tester measures vulcanization curve.
The rubber non-rotor vulcanization tester is used to measure the curve of torque versus time during the vulcanization process, in order to assess the crosslinking degree and vulcanization characteristics of rubber.